Ambient and unobtrusive cardiorespiratory monitoring techniques

被引:118
作者
Brüser, Christoph [1 ]
Antink, Christoph Hoog [1 ]
Wartzek, Tobias [1 ]
Walter, Marian [1 ]
Leonhardt, Steffen [1 ]
机构
[1] Philips Chai. for Medical Information Technology, RWTH Aachen University, Aachen
关键词
BCG; capacitive ECG; cardiorespiratory monitoring; laser; non-contact monitoring; PPG; PPGI; radar; SCG; thermography; unobtrusive monitoring; video analysis;
D O I
10.1109/RBME.2015.2414661
中图分类号
学科分类号
摘要
Monitoring vital signs through unobtrusive means is a goal which has attracted a lot of attention in the past decade. This review provides a systematic and comprehensive review over the current state of the field of ambient and unobtrusive cardiorespiratory monitoring. To this end, nine different sensing modalities which have been in the focus of current research activities are covered: capacitive electrocardiography, seismo- and ballistocardiography, reflective photoplethysmography (PPG) and PPG imaging, thermography, methods relying on laser or radar for distance-based measurements, video motion analysis, as well as methods using high-frequency electromagnetic fields. Current trends in these subfields are reviewed. Moreover, we systematically analyze similarities and differences between these methods with respect to the physiological and physical effects they sense as well as the resulting implications. Finally, future research trends for the field as a whole are identified. © 2015 IEEE.
引用
收藏
页码:30 / 43
页数:13
相关论文
共 158 条
  • [31] Chee Y., Han J., Youn J., Park K.S., Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements, Physiol. Meas., 26, pp. 413-422, (2005)
  • [32] Zhu X., Chen W., Nemoto T., Kanemitsu Y., Kitamura K., Yamakoshi K., Wei D., Real-time monitoring of respiration rhythm and pulse rate during sleep, IEEE Trans. Biomed. Eng., 53, 12, pp. 2553-2563, (2006)
  • [33] Heise D., Skubic M., Monitoring pulse and respiration with a non-invasive hydraulic bed sensor, Proc. IEEE 32nd Annu. Int. Conf. Eng. Med. Biol. Soc., pp. 2119-2123, (2010)
  • [34] Watanabe K., Kurihara Y., Tanaka H., Ubiquitous health monitoring at home sensing of human biosignals on flooring, on tatami mat, in the bathtub, andin the lavatory, IEEE Sens. J., 9, 12, pp. 1847-1855, (2009)
  • [35] Brink M., Muller C.H., Schierz C., Contact-free measurement of heart rate, respiration rate, and body movements during sleep, Behav. Res. Methods, 38, 3, pp. 511-521, (2006)
  • [36] Choi B.H., Chung G.S., Lee J.-S., Jeong D.-U., Park K.S., Slow-wave sleep estimation on a load-cell-installed bed: A non-constrained method, Physiol. Meas., 30, 11, pp. 1163-1170, (2009)
  • [37] Inan O.T., Etemadi M., Wiard R.M., Giovangrandi L., Kovacs G.T.A., Robust ballistocardiogram acquisition for home monitoring, Physiol. Meas., 30, pp. 169-185, (2009)
  • [38] Spillman Jr.W.B., Mayer M., Bennett J., Gong J., Meissner K.E., Davis B., Claus R.O., Muelenaer Jr.A.A., Xu X., A 'smart' bed for non-intrusive monitoring of patient physiological factors, Meas. Sci. Technol., 15, pp. 1614-1620, (2004)
  • [39] Sprager S., Zazula D., Heartbeat and respiration detection from optical interferometric signals by using a multimethod approach, IEEE Trans. Biomed. Eng., 59, 10, pp. 2922-2929, (2012)
  • [40] Bruser C., Kerekes A., Winter S., Leonhardt S., Multi-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed, Proc. IEEE 34th Annu. Int. Conf. Eng. Med. Biol. Soc., pp. 5042-5045, (2012)