Heat transfer characteristics in closed-loop spray cooling of micro-structured surfaces

被引:1
作者
Zhang, Wei [1 ]
Wang, Zhaoliang [1 ]
Xu, Minghai [1 ]
机构
[1] College of Architecture and Storage Engineering, China University of Petroleum
来源
Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams | 2012年 / 24卷 / 09期
关键词
Critical heat flux; Micro-structured surface; Phase change heat transfer; Spray cooling;
D O I
10.3788/HPLPB20122409.2053
中图分类号
学科分类号
摘要
With water as the working fluid, experiments on the heat transfer characteristics of spray cooling of micro-structured surfaces were performed in a closed loop system. Experimental data were analyzed in the view of the ratio between convective heat transfer and phase change heat transfer. The results indicate that heat transfer is obviously enhanced for micro-channel surfaces relative to the flat surface because of higher phase change heat transfer. For the geometries tested at lower surface temperature, the straight finned surface has the largest heat flux; while at higher surface temperature, the cubic pin finned surface has the largest heat flux. Heat fluxes of all the surfaces grow with increasing flow rates, except for the straight finned surface under lower surface temperature. The ratio of phase change to total heat transfer is bigger than 20% for the flat surface, and higher than 50% for micro-structured surfaces. Critical heat fluxes of 159.1, 120.2, and 109.8 W/cm 2 are attained for cubic pin finned, straight finned and flat surfaces respectively when the flow rate is 15.9 mL/min, and the corresponding evaporation efficiencies are 96.0%, 72.5%, 67.1%.
引用
收藏
页码:2053 / 2058
页数:5
相关论文
共 23 条
  • [1] Li D., Wang W., Simulation of full cone nozzle spray cooling performance in single phase, Fluid Machinery, 38, 6, pp. 64-68, (2010)
  • [2] Zhou L., Tang D., Du X., Et al., High power laser weapons and their cooling systems, Laser and Optoelectronics Progress, 44, 8, pp. 34-38, (2007)
  • [3] Wu D., Gao S., Lu W., Et al., Design of high efficient copper micro-channels cooler for diode laser, High Power Laser and Particle Beams, 16, 7, pp. 840-842, (2004)
  • [4] Kim J., Spray cooling heat transfer: The state of art, International Journal of Heat and Fluid Flow, 28, 1, pp. 753-767, (2007)
  • [5] Wang Y., Liu M., Liu D., Et al., Experiment study on spray cooling for high-power laser, High Power Laser and Particle Beams, 21, 12, pp. 1761-1766, (2009)
  • [6] Chen R., Chow L.C., Navedo J.E., Effects of spray characteristics on critical heat flux in subcooled water spray cooling, International Journal of Heat and Mass Transfer, 45, 2, pp. 4033-4043, (2002)
  • [7] Chen R., Chow L.C., Navedo J.E., Optimal spray characteristics in water spray cooling, International Journal of Heat and Mass Transfer, 47, 9, pp. 5095-5099, (2004)
  • [8] Daniel P.R., Chen R., Chow L.C., Bubble behavior and nucleate boiling heat transfer in saturated FC-72 spray cooling, Journal of Heat Transfer, 124, 5, pp. 63-72, (2002)
  • [9] Chen R., Tan D.S., Lin K.C., Et al., Droplet and bubble dynamics in saturated FC-72 spray cooling on a smooth surface, Journal of Heat Transfer, 130, 1, pp. 1-9, (2008)
  • [10] Wang Y., Liu M., Liu D., Et al., Experiment study on non-boiling heat transfer performance in spray cooling for high-power laser, Chinese Journal of Lasers, 36, 8, pp. 1973-1978, (2009)