Scaling analysis of the transient from forced circulation to natural circulation

被引:0
|
作者
Shi Y. [1 ]
Yang F. [1 ]
Li Y. [1 ]
机构
[1] State Nuclear Power Technology Research & Development Centre, Beijing
来源
| 1600年 / Atomic Energy Press卷 / 37期
关键词
Forced circulation; Main pump coast-down; Natural circulation; Scaling analysis;
D O I
10.13832/j.jnpe.2016.02.0038
中图分类号
学科分类号
摘要
Integral thermal hydraulics test plays a key role in the safety verification of PWR. The scaling analysis of the circulation characteristics in the primary loop provides the theoretical basis for the integral test facility design. Based on the two-phase drift flow model, the governing equations of forced circulation and natural circulation were established. The initial conditions were applied to nondimensionalize the governing equations resulting in the similarity criterions of transient from the forced circulation to the natural circulation for the integral test facility. The experimental method which can simulate the prototype main pump coast-down and satisfy the similarity requirements of the transient between circulations was proposed. © 2016, Yuan Zi Neng Chuban She. All right reserved.
引用
收藏
页码:38 / 42
页数:4
相关论文
共 3 条
  • [1] Ishii M., Kataoka I.S., caling laws for thermal-hydraulic system under single phase and tow-phase natural circulation, Nuclear Engineering and Design, 81, pp. 411-425, (1984)
  • [2] Reyes J., Hochreiter L., Scaling analysis for the OSU AP600 test facility (APEX), Nuclear Engineering and Design, 186, pp. 53-109, (1998)
  • [3] Levy S., Forced convection subcooled boiling prediction of vapor volumetric fraction, Internal Journal of Heat Mass Transfer, 10, (1967)