Density characterization of gold foam sample with abnormal surface using X-ray CT technology

被引:0
作者
Research Center of Laser Fusion, CAEP, P.O. Box 919-987, Mianyang, China [1 ]
不详 [2 ]
不详 [3 ]
机构
[1] Research Center of Laser Fusion, CAEP, P.O. Box 919-987, Mianyang
[2] Institute of Applied Electronics, CAEP, P.O. Box 919-1005, Mianyang
[3] National X-ray Digital Imaging Instrument Center, P.O. Box 919-1005, Mianyang
来源
Qiangjiguang Yu Lizishu | / 3卷
关键词
Abnormal surface; CT; Density characterization; Gold foam; Volume reconstruction;
D O I
10.11884/HPLPB201527.032023
中图分类号
学科分类号
摘要
Gold foam is one of the most important materials used in ICF experimental research, while it is hard to precisely measure the volume of the gold foam in its density characterization. Here we reported one method of volume reconstruction by using X ray CT technology. By using this method, the density of our prepared gold foam with abnormal surface is determined to be 978.68 mg/cm-3. To validate the accuracy of this method, comparison experiments between this method and a specific gravity bottle method have been performed by using plasticine samples. The results show that the relative error value is less than 1%. ©, 2015, Editorial Office of High Power Laser and Particle Beams. All right reserved.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Increasing throughput in x-ray computed tomography measurement of surface topography using sinogram interpolation
    Korner, Lars
    Lawes, Simon
    Bate, David
    Newton, Lewis
    Senin, Nicola
    Leach, Richard
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (12)
  • [22] Estimation of the density of pomegranate fruit and their fractions using X-ray computed tomography calibrated with polymeric materials
    Arendse, Ebrahiema
    Fawole, Olaniyi Amos
    Magwaza, Lembe Samukelo
    Opara, Umezuruike Linus
    [J]. BIOSYSTEMS ENGINEERING, 2016, 148 : 148 - 156
  • [23] Characterization of Geometry and Surface Texture of AlSi10Mg Laser Powder Bed Fusion Channels Using X-ray Computed Tomography
    Klingaa, Christopher G.
    Zanini, Filippo
    Mohanty, Sankhya
    Carmignato, Simone
    Hattel, Jesper H.
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [24] Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging
    Sarapata, A.
    Chabior, M.
    Cozzini, C.
    Sperl, J. I.
    Beque, D.
    Langner, O.
    Coman, J.
    Zanette, I.
    Ruiz-Yaniz, M.
    Pfeiffer, F.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (10)
  • [25] Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
    Utsunomiya, D
    Tomiguchi, S
    Shiraishi, S
    Yamada, K
    Honda, T
    Kawanaka, K
    Kojima, A
    Awai, K
    Yamashita, Y
    [J]. ANNALS OF NUCLEAR MEDICINE, 2005, 19 (06) : 485 - 489
  • [26] Initial experience with X-ray ct based attenuation correction in myocardial perfusion spect imaging using a combined spect/ct system
    Daisuke Utsunomiya
    Seiji Tomiguchi
    Shinya Shiraishi
    Koichiro Yamada
    Tsuyoshi Honda
    Koichi Kawanaka
    Akihiro Kojima
    Kazuo Awai
    Yasuyuki Yamashita
    [J]. Annals of Nuclear Medicine, 2005, 19 : 485 - 489
  • [27] Detection of COVID-19 from CT and Chest X-ray Images Using Deep Learning Models
    Zouch, Wassim
    Sagga, Dhouha
    Echtioui, Amira
    Khemakhem, Rafik
    Ghorbel, Mohamed
    Mhiri, Chokri
    Ben Hamida, Ahmed
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2022, 50 (07) : 825 - 835
  • [28] Measurement of changes in trabecular bone at fracture sites using X-ray CT and automated image registration and processing
    Lynch, JA
    Grigoryan, M
    Fierlinger, A
    Guermazi, A
    Zaim, S
    MacLean, DB
    Genant, HK
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 362 - 367
  • [29] Quality improvement of X-ray Ct images by estimation of the mechanical misalignment in a projection image using an iterative method
    Noguchi K.
    Takahashi S.
    Suzuki D.
    Teramoto A.
    [J]. Noguchi, Kenji (noguchi@nagoya-denki.co.jp), 1600, Institute of Electrical Engineers of Japan (137): : 213 - 219
  • [30] Detection of COVID-19 from CT and Chest X-ray Images Using Deep Learning Models
    Wassim Zouch
    Dhouha Sagga
    Amira Echtioui
    Rafik Khemakhem
    Mohamed Ghorbel
    Chokri Mhiri
    Ahmed Ben Hamida
    [J]. Annals of Biomedical Engineering, 2022, 50 : 825 - 835