Prompt Gamma Rays Detected with a BGO Block Compton Camera Reveal Range Deviations of Therapeutic Proton Beams

被引:32
|
作者
Hueso-Gonzalez F. [1 ,2 ]
Pausch G. [1 ,3 ,5 ]
Petzoldt J. [3 ,4 ,5 ]
Romer K.E. [1 ]
Enghardt W. [1 ,5 ,6 ]
机构
[1] Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology, Dresden
[2] Target Systemelektronik GmbH, Wuppertal
[3] OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden
[4] Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve
[5] University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden
[6] German Cancer Consortium, German Cancer Research Center
来源
| 1600年 / Institute of Electrical and Electronics Engineers Inc.卷 / 01期
基金
欧盟地平线“2020”;
关键词
BGO block detector; Compton camera; prompt gamma ray imaging; proton therapy; range verification;
D O I
10.1109/TNS.2016.2622162
中图分类号
学科分类号
摘要
The dose deposition profile of protons is interesting for tumour treatment due to the increased ionization density at the end of their track. However, the inaccurate knowledge of the proton stopping point limits the precision of the therapy. Prompt gamma rays, a by-product of the irradiation, are candidates for an indirect measurement of the particle range. Compton cameras have been proposed for prompt gamma ray imaging, but struggle with high trigger rates and low coincident efficiency. The feasibility in a clinical environment has yet to be proved. At Universitäts Protonen Therapie Dresden, two bismuth germanate (BGO) block detectors arranged face-to-face are deployed for imaging tests with a homogeneous target irradiated by a proton pencil beam. Shifts of the target, increase of its thickness and beam energy variation experiments are conducted. Each measurement lasts about 15 minutes at a low proton beam current. The effect of one centimetre proton range deviations on the backprojected images is analysed. The number of valid Compton events as well as the trigger rate expected in a realistic treatment plan with pencil beam scanning are estimated. The results support the use of a high density material despite its moderate energy resolution, in order to maximize the coincident efficiency. Nevertheless, they discourage the applicability of a two-plane Compton camera in a clinical scenario with usual beam currents. © 2017 IEEE.
引用
收藏
页码:76 / 86
页数:10
相关论文
共 33 条
  • [21] Prompt gamma imaging with a slit camera for real-time range control in proton therapy
    Smeets, J.
    Roellinghoff, F.
    Prieels, D.
    Stichelbaut, F.
    Benilov, A.
    Busca, P.
    Fiorini, C.
    Peloso, R.
    Basilavecchia, M.
    Frizzi, T.
    Dehaes, J. C.
    Dubus, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11) : 3371 - 3405
  • [22] Deep residual fully connected neural network classification of Compton camera based prompt gamma imaging for proton radiotherapy
    Barajas, Carlos A. A.
    Polf, Jerimy C. C.
    Gobbert, Matthias K. K.
    FRONTIERS IN PHYSICS, 2023, 11
  • [23] Prompt gamma energy integration: a new method for online-range verification in proton therapy with pulsed-beams
    Everaere, Pierre
    Dauvergne, Denis
    Gallin-Martel, Marie-Laure
    Herault, Joel
    Koudia, Ayoub
    Koumeir, Charbel
    Letang, Jean Michel
    Testa, Etienne
    FRONTIERS IN PHYSICS, 2024, 12
  • [24] New algorithm to estimate proton beam range for multi-slit prompt- gamma camera
    Ku, Youngmo
    Jung, Jaerin
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3422 - 3428
  • [25] Light-transport incorporated plastic scintillator response to prompt gamma-rays for use in range verification of proton therapy
    Shahsavari, A.
    Ghal-Eh, N.
    Najafabadi, R. Izadi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1049
  • [27] Measuring Prompt Gamma Emission Profiles with a Multi-Stage Compton Camera During Proton Beam Irradiaition: Initial Studies
    Polf, J.
    Brown, S.
    Mann, J.
    Mackin, D.
    Zheng, Y.
    McCleskey, M.
    Beddar, S.
    He, Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 183 - 183
  • [28] Hybrid treatment verification based on prompt gamma rays and fast neutrons: multivariate modelling for proton range determination
    Schellhammer, Sonja M.
    Meric, Ilker
    Loeck, Steffen
    Koegler, Toni
    FRONTIERS IN PHYSICS, 2023, 11
  • [29] Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera
    Roellinghoff, F.
    Benilov, A.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Janssens, G.
    Krimmer, J.
    Letang, J. M.
    Pinto, M.
    Prieels, D.
    Ray, C.
    Smeets, J.
    Stichelbaut, F.
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) : 1327 - 1338
  • [30] Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system
    Ku, Youngmo
    Choi, Sehoon
    Cho, Jaeho
    Jang, Sehyun
    Jeong, Jong Hwi
    Kim, Sung Hun
    Cho, Sungkoo
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3140 - 3149