Prompt Gamma Rays Detected with a BGO Block Compton Camera Reveal Range Deviations of Therapeutic Proton Beams

被引:32
|
作者
Hueso-Gonzalez F. [1 ,2 ]
Pausch G. [1 ,3 ,5 ]
Petzoldt J. [3 ,4 ,5 ]
Romer K.E. [1 ]
Enghardt W. [1 ,5 ,6 ]
机构
[1] Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology, Dresden
[2] Target Systemelektronik GmbH, Wuppertal
[3] OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden
[4] Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve
[5] University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden
[6] German Cancer Consortium, German Cancer Research Center
来源
| 1600年 / Institute of Electrical and Electronics Engineers Inc.卷 / 01期
基金
欧盟地平线“2020”;
关键词
BGO block detector; Compton camera; prompt gamma ray imaging; proton therapy; range verification;
D O I
10.1109/TNS.2016.2622162
中图分类号
学科分类号
摘要
The dose deposition profile of protons is interesting for tumour treatment due to the increased ionization density at the end of their track. However, the inaccurate knowledge of the proton stopping point limits the precision of the therapy. Prompt gamma rays, a by-product of the irradiation, are candidates for an indirect measurement of the particle range. Compton cameras have been proposed for prompt gamma ray imaging, but struggle with high trigger rates and low coincident efficiency. The feasibility in a clinical environment has yet to be proved. At Universitäts Protonen Therapie Dresden, two bismuth germanate (BGO) block detectors arranged face-to-face are deployed for imaging tests with a homogeneous target irradiated by a proton pencil beam. Shifts of the target, increase of its thickness and beam energy variation experiments are conducted. Each measurement lasts about 15 minutes at a low proton beam current. The effect of one centimetre proton range deviations on the backprojected images is analysed. The number of valid Compton events as well as the trigger rate expected in a realistic treatment plan with pencil beam scanning are estimated. The results support the use of a high density material despite its moderate energy resolution, in order to maximize the coincident efficiency. Nevertheless, they discourage the applicability of a two-plane Compton camera in a clinical scenario with usual beam currents. © 2017 IEEE.
引用
收藏
页码:76 / 86
页数:10
相关论文
共 33 条
  • [11] Noise evaluation of prompt-gamma technique for proton-therapy range verification using a Compton Camera
    Ortega, P. G.
    Torres-Espallardo, I.
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Ferrari, A.
    Gillam, J. E.
    Lacasta, C.
    Llosa, G.
    Oliver, J.
    Rafecas, M.
    Sala, P. R.
    Solevi, P.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [12] Comparison of reconstructed prompt gamma emissions using maximum likelihood estimation and origin ensemble algorithms for a Compton camera system tailored to proton range monitoring
    Lozano, Ingrid Valencia
    Dedes, George
    Peterson, Steve
    Mackin, Dennis
    Zoglauer, Andreas
    Beddar, Sam
    Avery, Stephen
    Polf, Jerimy
    Parodi, Katia
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (02): : 124 - 134
  • [13] Optimization of the Compton camera for measuring prompt gamma rays in boron neutron capture therapy
    Gong, Chun-hui
    Tang, Xiao-bin
    Shu, Di-yun
    Yu, Hai-yan
    Geng, Chang-ran
    APPLIED RADIATION AND ISOTOPES, 2017, 124 : 62 - 67
  • [14] Range verification of passively scattered proton beams using prompt gamma-ray detection
    Verburg, Joost M.
    Testa, Mauro
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03) : 1019 - 1029
  • [15] Computational model for detector timing effects in Compton-camera based prompt-gamma imaging for proton radiotherapy
    Maggi, Paul
    Peterson, Steve
    Panthi, Rajesh
    Mackin, Dennis
    Yang, Hao
    He, Zhong
    Beddar, Sam
    Polf, Jerimy
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12)
  • [16] Classification of Compton Camera Based Prompt Gamma Imaging for Proton Radiotherapy by Random Forests
    Barajas, Carlos A.
    Kroiz, Gerson C.
    Gobbert, Matthias K.
    Polf, Jerimy C.
    2021 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND COMPUTATIONAL INTELLIGENCE (CSCI 2021), 2021, : 308 - 311
  • [17] Accuracy of using high-energy prompt gamma to verify proton beam range with a Compton camera: A Monte Carlo simulation study
    Huang, Hsuan-Ming
    Jan, Meei-Ling
    APPLIED RADIATION AND ISOTOPES, 2018, 142 : 173 - 180
  • [18] Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification
    Nenoff, Lena
    Priegnitz, Marlen
    Janssens, Guillaume
    Petzoldt, Johannes
    Wohlfahrt, Patrick
    Trezza, Anna
    Smeets, Julien
    Pausch, Guntram
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 534 - 540
  • [19] Performance Evaluation of a Multiple-Scattering Compton Imager for Distribution of Prompt Gamma-Rays in Proton Therapy
    Lee, Taewoong
    Lee, Hyounggun
    Kim, Younghak
    Lee, Wonho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (02) : 184 - 191
  • [20] Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters
    Lopes, Patricia Cambraia
    Clementel, Enrico
    Crespo, Paulo
    Henrotin, Sebastien
    Huizenga, Jan
    Janssens, Guillaume
    Parodi, Katia
    Prieels, Damien
    Roellinghoff, Frauke
    Smeets, Julien
    Stichelbaut, Frederic
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15) : 6063 - 6085