Recovering Low-Grade Heat from Flue Gas in a Coal-Fired Thermal Power Unit

被引:0
|
作者
Huang, Linbin [1 ,2 ]
Chen, Guoqing [1 ]
Xu, Xiang [3 ]
Tan, Rui [2 ]
Gao, Xinglong [4 ]
Zhang, Haifeng [4 ]
Yu, Jie [3 ]
机构
[1] State Key Lab Low Carbon Smart Coal Fired Power Ge, Nanjing 210023, Peoples R China
[2] Guoneng Nanjing Elect Power Testing & Res Co Ltd, Nanjing 210046, Peoples R China
[3] Huazhong Univ Sci & Technol, State Key Lab Coal Combust, Wuhan 430074, Peoples R China
[4] Guoneng Changzhou Secondary Power Generat Co Ltd, Changzhou 213000, Peoples R China
关键词
waste heat utilization; air preheater bypass; heat pump; exergy efficiency; coal consumption rate; BYPASS FLUE; SYSTEM; DESIGN; PLANTS; PERFORMANCE; EFFICIENCY; ECONOMIZER;
D O I
10.3390/en17205204
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To achieve the goals of carbon peaking and carbon neutrality, the retrofitting of existing coal-fired power plants is crucial to achieving energy-saving and emission reduction goals. A conventional recovery system of waste heat typically occurs downstream of the air preheater, where the energy quality in flue gas is low, resulting in limited coal-saving benefits. This study proposes a scheme involving a flue gas exchanger bypassing the air preheater and low-temperature economizers, which is used to transfer the waste heat from flue gas to primary and secondary air (System I). Additionally, a heat pump can be introduced to provide supplementary energy for primary and secondary air, as well as the condensate from the steam turbine (System II). The coal consumption rate and exergy efficiency are used to evaluate the two schemes. The results show that both waste heat recovery systems can increase the power output of the coal-fired unit by recovering waste heat. System II can boost power output by approximately 13.98 MW. The power increase in both waste heat recovery systems show a declining trend as the unit load decreases. This increased power is primarily attributed to the medium- and low-pressure cylinders, while the contributions from ultra-high-pressure and high-pressure cylinders are negligible. The increased power output for the medium-pressure cylinder ranges from approximately 3.49 to 3.58 MW, while the low-pressure cylinder has an increased power output of around 10.10 to 10.19 MW. The coal consumption rate is decreased from 250.3 g/(kW<middle dot>h) to 247.5 g/(kW<middle dot>h) under a full load condition for both systems, which can be augmented at lower load conditions. System II outperforms System I at 30% load condition, achieving a reduced coal consumption rate of 3.36 g/(kW<middle dot>h). System I has an exergy efficiency of 40%, while System II shows a higher efficiency of 44%.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Utilizing flue gas low-grade waste heat and furnace excess heat to produce syngas and sulfuric acid recovery in coal-fired power plant
    Ouyang, Tiancheng
    Xu, Jisong
    Qin, Peijia
    Cheng, Liang
    ENERGY, 2022, 258
  • [2] Use of waste heat recovery system for cleaning flue gas in a coal-fired power unit
    Szulc, Piotr
    Tietze, Tomasz
    PRZEMYSL CHEMICZNY, 2017, 96 (04): : 921 - 925
  • [3] Flue Gas Heat Recovery in High Efficient Coal-fired Power Plant
    Buchta, Janusz
    Oziemski, Andrzej
    PROCEEDINGS OF THE 2019 20TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2019, : 507 - 512
  • [4] New heat integration system with bypass flue based on the rational utilization of low-grade extraction steam in a coal-fired power plant
    Han, Yu
    Xu, Gang
    Zheng, Qingqing
    Xu, Cheng
    Hu, Yue
    Yang, Yongping
    Lei, Jing
    APPLIED THERMAL ENGINEERING, 2017, 113 : 460 - 471
  • [5] An Improved System for Utilizing Low-Temperature Waste Heat of Flue Gas from Coal-Fired Power Plants
    Huang, Shengwei
    Li, Chengzhou
    Tan, Tianyu
    Fu, Peng
    Xu, Gang
    Yang, Yongping
    ENTROPY, 2017, 19 (08):
  • [6] Proposed Partial Repowering of a Coal-Fired Power Plant Using Low-Grade Solar Thermal Energy
    Hong, Hui
    Zhao, Yawen
    Jin, Hongguang
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2011, 14 (01) : 21 - 28
  • [7] Flue gas desulfurization methods in coal-fired power plant
    Michalski, Jacek A.
    PRZEMYSL CHEMICZNY, 2017, 96 (04): : 731 - 736
  • [8] Flue gas treatment system for coal-fired power plants
    Mori, A.
    Yamada, H.
    Kuroda, H.
    Hitachi Review, 1980, 29 (06): : 303 - 306
  • [9] Speciation of Mercury in Coal-Fired Power Station Flue Gas
    Shah, Pushan
    Strezov, Vladimir
    Nelson, Peter F.
    ENERGY & FUELS, 2010, 24 (01) : 205 - 212
  • [10] CO2 fixation from the flue gas on coal-fired thermal power plant by microalgae
    EPDC Environmental Engineering, Service Co, Ltd
    Energy Convers Manage, 6-9 (717-720):