Analysis on kinematics and dynamics of human arm movement toward upper limb exoskeleton robot control part 1: System model and kinematic constraint

被引:2
作者
Kim, Hyunchul [1 ]
Lee, Choon-Young [2 ]
机构
[1] University of California, Santa Cruz
来源
Kim, H. (hyunchul78@gmail.com) | 1600年 / Institute of Control, Robotics and Systems卷 / 18期
关键词
Dynamics; Exoskeleton; Kinematics; Redundancy;
D O I
10.5302/J.ICROS.2012.18.12.1106
中图分类号
学科分类号
摘要
To achieve synchronized motion between a wearable robot and a human user, the redundancy must be resolved in the same manner by both systems. According to the seven DOF (Degrees of Freedom) human arm model composed of the shoulder, elbow, and wrist joints, positioning and orientating the wrist in space is a task requiring only six DOFs. Due to this redundancy, a given task can be completed by multiple arm configurations, and thus there exists no unique mathematical solution to the inverse kinematics. This paper presents analysis on the kinematic and dynamic aspect of the human arm movement and their effect on the redundancy resolution of the human arm based on a seven DOF manipulator model. The redundancy of the arm is expressed mathematically by defining the swivel angle. The final form of swivel angle can be represented as a linear combination of two different swivel angles achieved by optimizing different cost functions based on kinematic and dynamic criteria. The kinematic criterion is to maximize the projection of the longest principal axis of the manipulability ellipsoid for the human arm on the vector connecting the wrist and the virtual target on the head region. The dynamic criterion is to minimize the mechanicalwork done in the joint space for each two consecutive points along the task space trajectory. As a first step, the redundancy based on the kinematic criterion will be thoroughly studied based on the motion capture data analysis. Experimental results indicate that by using the proposed redundancy resolution criterion in the kinematic level, error between the predicted and the actual swivel angle acquired from the motor control system is less than five degrees. © ICROS 2012.
引用
收藏
页码:1106 / 1114
页数:8
相关论文
共 2 条
  • [1] Isotropy of an upper limb exoskeleton and the kinematics and dynamics of the human arm
    Perry, Joel C.
    Powell, Janet M.
    Rosen, Jacob
    Applied Bionics and Biomechanics, 2009, 6 (02) : 175 - 191
  • [2] The human arm kinematics and dynamics during daily activities - Toward a 7 DOF upper limb powered exoskeleton
    Rosen, J
    Perry, JC
    Manning, N
    Burns, S
    Hannaford, B
    2005 12TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS, 2005, : 532 - 539