Development of continuous monitoring system with FT-IR for gas generation behavior in Coke Oven

被引:0
作者
机构
[1] Advanced Technology Research Lab., Nippon Steel Corp., Futtsu 293-8511
[2] Yawata Works, Nippon Steel Corp.
来源
Nishifuji, M. | 2005年 / Iron and Steel Institute of Japan卷 / 91期
关键词
Coke oven; Coke oven gas; FT-IR; Gas monitoring system;
D O I
10.2355/tetsutohagane1955.91.2_299
中图分类号
学科分类号
摘要
A continuous monitoring system for gas generation in coke oven has been established with the Fourier-transform infrared spectroscopic analyzer (FT-IR) as a detector. Coke oven gas (COG) was sampled in an ascension pipe by a pump. COG, passed through traps for removing tar and mist, was led to the detector located about 20 m from the sampling position. COG was monitored with 50 times dilution by nitrogen gas because the concentrations of component gases are too high for the FT-IR measurement. Using this system, the COG of a coke oven was measured continuously for about 20 h. By monitoring the generation behavior of COG, it was possible to characterize the details of the coking reaction in a coke oven. It was shown that different combinations of coals result in different COG generation behavior.
引用
收藏
页码:299 / 303
页数:4
相关论文
共 5 条
  • [1] Okuno Y., Met. Technol. (Jpn.), 71, (2001)
  • [2] Imai K., Tatsuta M., Kitamura T., Fujitetsu Giho, 4, (1954)
  • [3] Yoshino Y., Tsuchihashi K., Komatsu Y., Coke Circular, 35, (1986)
  • [4] Fujishima Y.I., Tanabe H., Coke Circular, 34, (1985)
  • [5] Nishifuji M., Fujioka Y., Saito K., Tetsu-to-Hagané, 82, (1996)