Sampling efficiency of flow-through air sampler: Effect of sampling rate

被引:0
|
作者
Cai, Qiu-liang [1 ,2 ,3 ,4 ]
Tong, Lei [3 ,4 ,5 ]
Zhong, Ning [6 ]
Zheng, Jie [3 ,4 ,5 ]
He, Meng-meng [3 ,4 ,5 ]
Xiao, Hang [3 ,4 ,5 ]
机构
[1] Baise Univ, Guangxi Key Lab Urban Water Environm, Baise 533000, Peoples R China
[2] Baise Univ, Key Lab Guangxi Univ Ecol Environm Anal & Pollut C, Baise 533000, Peoples R China
[3] Chinese Acad Sci, Inst Urban Environm, Key Lab Urban Environm & Hlth, Xiamen 361021, Peoples R China
[4] Chinese Acad Sci, Inst Urban Environm, Ningbo Observat & Res Stn, Xiamen 361021, Peoples R China
[5] CAS Haixi Ind Technol Innovat Ctr Beilun, Ningbo Key Lab Urban Environm Pollut & Control, Ningbo 315830, Peoples R China
[6] Minnan Normal Univ, Zhangzhou 363000, Peoples R China
基金
中国国家自然科学基金;
关键词
Sampling rate; Theoretical plate number; Breakthrough volume; Frontal chromatographic theory; LSER; Flow-through sampler; SEMIVOLATILE ORGANIC-COMPOUNDS; FLAME RETARDANTS; CHROMATOGRAPHY; DIFFUSION; PRESSURE; VELOCITY;
D O I
10.1016/j.chroma.2024.465474
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Flow Through Sampler (FTS) serves as an efficient wind-powered active sampling device, enabling the collection of a significant air volume within a short duration. Throughout the actual sampling process, the sampling rate of FTS experiences continuous fluctuations, highlighting the need for in-depth investigation into its impact on breakthrough. In this study, we interconnected the FTS sampling column with three distinct pumps, operating at five varied sampling rates under 293 K and 303 K; and breakthrough profiles of PCBs, PAHs and OCPs on the FTS sampling column were investigated to understand the impacts of sampling rate, expressed as linear wind velocity through the cross section of FTS tube (u) on the sampling efficiency of the sampling column. It revealed that the number of theoretical plates (N) and the logarithm of breakthrough volume (logVB) of compounds on the FTS-PUF column exhibit linear relationships with the inverse of wind velocity (1/u). The slopes of the fitted lines (KNu) are closely associated with the volatility of the compounds. Compounds with volatility experience a greater impact from variations in wind velocity on their N value on the sampling column. The effect on the most volatile PCBs surpasses that of PAHs and OCPs. Moreover, the slopes of logVB for different compounds affected by wind speed (KVB-u), display a significant correlation with compound volatility (logPL). Wind speed exerts a stronger influence on the breakthrough volume of low volatile compounds compared to volatile compounds. Multiple linear regression and LSER analysis further confirms a significant positive correlation between N and logVB across different temperatures and wind velocities (log(VB/m3)=2010/(T/K)0.00066/(u/(m/s))+0.55N-5.41, R2=0.83, n = 423, p = 0). Therefore, the collection performance of the FTS-PUF sampling column for all types of compounds can be predicted under varying temperatures and wind velocitiess/ sampling rates. Given the known sampled air volume, the breakthrough level for any chemicals can be estimated, which provids valuable data support for accurate monitoring of atmospheric organic pollutant concentrations.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Effect of sampler and manikin conductivity on the sampling efficiency of manikin-mounted personal samplers
    Smith, J
    Bartley, D
    AEROSOL SCIENCE AND TECHNOLOGY, 2003, 37 (01) : 79 - 81
  • [22] REUTER CENTRIFUGAL AIR SAMPLER - MEASUREMENT OF EFFECTIVE AIR-FLOW RATE AND COLLECTION EFFICIENCY
    MACHER, JM
    FIRST, MW
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 45 (06) : 1960 - 1962
  • [23] Effect of selected sampling media, flow rate, and time on the sampling efficiency of a liquid impinger packed with glass beads for the collection of airborne viruses
    Chen, Yen-Chi
    Wang, I-Jen
    Cheng, Chih-Ching
    Wu, Yu-Chiao
    Bai, Chun-Hsuan
    Yu, Kuo-Pin
    AEROBIOLOGIA, 2021, 37 (02) : 243 - 252
  • [24] Effect of selected sampling media, flow rate, and time on the sampling efficiency of a liquid impinger packed with glass beads for the collection of airborne viruses
    Yen-Chi Chen
    I-Jen Wang
    Chih-Ching Cheng
    Yu-Chiao Wu
    Chun-Hsuan Bai
    Kuo-Pin Yu
    Aerobiologia, 2021, 37 : 243 - 252
  • [25] EFFECT OF CUP PROPERTIES, SAMPLER GEOMETRY, AND VACUUM ON THE SAMPLING RATE OF POROUS CUP SAMPLERS
    MORRISON, RD
    LOWERY, B
    SOIL SCIENCE, 1990, 149 (05) : 308 - 316
  • [26] WEDDING AMBIENT AEROSOL SAMPLING INLET FOR AN INTERMEDIATE FLOW-RATE (4 CFM) SAMPLER
    WEDDING, JB
    WEIGAND, MA
    LOGITKE, MW
    BAUMGARDNER, R
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1983, 17 (07) : 379 - 383
  • [27] Sampling efficiency of particles in stationary air
    Yoshida, Hideto
    Uragami, Masayuki
    Masuda, Hiroaki
    Iinoya, Koichi
    1600, Society of Chemical Engineers, Japan (04):
  • [28] Groundwater Sampling: Flow-Through Bailer Passive Method Versus Conventional Purge Method
    Gomo, M.
    Vermeulen, D.
    Lourens, P.
    NATURAL RESOURCES RESEARCH, 2018, 27 (01) : 51 - 65
  • [29] Flow-through sampling for electrophoresis-based microfluidic chips using hydrodynamic pumping
    Lin, YH
    Lee, GB
    Li, CW
    Huang, GR
    Chen, SH
    JOURNAL OF CHROMATOGRAPHY A, 2001, 937 (1-2) : 115 - 125
  • [30] EVALUATION OF THE MICROBIOLOGICAL SAMPLING EFFICIENCY OF A CENTRIFUGAL AIR-SAMPLING DEVICE
    DELMORE, RP
    COROSA, PA
    PISCIA, P
    THOMPSON, WN
    DEVELOPMENTS IN INDUSTRIAL MICROBIOLOGY, 1981, 22 : 617 - 626