Thermal analysis of an electric power transformer inside an enclosure–a case study

被引:1
作者
Abdolzadeh M. [1 ]
Khoshabi A. [2 ]
Mehrabian M.A. [2 ]
机构
[1] Department of Mechanical Engineering, Graduate University of Advanced Technology, Kerman
[2] Department of Mechanical Engineering, Shahid Bahonar University of Kerman
来源
Abdolzadeh, M. (mo.abdolzadeh@gmail.com) | 1600年 / Taylor and Francis Ltd.卷 / 38期
关键词
enclosure; experimental data; flow and heat transfer; numerical; three-dimensional; Transformer;
D O I
10.1080/01430750.2015.1086678
中图分类号
学科分类号
摘要
Electric transformer inside an enclosure is used in the medium power transmission lines. It reduces the power losses more than other transformers in the transmission lines. In this study, thermal performance of a transformer inside an enclosure was investigated numerically and experimentally under different operating conditions. The experimental data were collected while the transformer was working in real operating conditions. The 3D numerical analysis was conducted and then verified with the experimental data. The results of this study show that despite lower power loss of the transformer, compared to the conventional transformers which are commonly installed on the overhead power line towers, the enclosure of the transformer has a serious problem of poor ventilation and it causes the transformer to run at higher temperature condition and this consequently decreases the transformer's efficiency. However, this problem can be fixed by implementing some changes in the enclosure's air vents and also by adding a fan on the roof of the enclosure. © 2015 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:250 / 258
页数:8
相关论文
共 12 条
[1]  
Beiza M., Ramos J.C., Rivas A., Anton R., Larraona G.S., Gastelurrutia J., de Miguel I., Zonal Thermal Model of the Ventilation of Underground Transformer Substations: Development and Parametric Study, Applied Thermal Engineering, 62, pp. 215-228, (2014)
[2]  
Duffie J.A., Beckman W.A., Solar Engineering of Thermal Processes, (1982)
[3]  
Gastelurrutia J., Ramos J.C., Larraona G.S., Rivas A., Izagirre J., Del Rio L., Numerical Modelling of Natural Convection of Oil Inside Distribution Transformers, Applied Thermal Engineering, 31, pp. 493-505, (2011)
[4]  
Gastelurrutia J., Ramos J.C., Rivas A., Larraona G.S., Izagirre J., del Rio L., Zonal Thermal Model of Distribution Transformer Cooling, Applied Thermal Engineering, 31, (2011)
[5]  
Godec Z., Sarunac R., Steady-state Temperature Rise of ONAN/ONAF/OFAF Transformer Formers, IEEE Proceedings-C, 139, 5, pp. 448-454, (1992)
[6]  
Holman J.P., Heat transfer, (2002)
[7]  
Iyi D., Hasan R., Penlington R., Numerical Simulation of 2D Turbulent Natural Convection of Humid Air in a Cavity Filled with Solid Objects, Procedia Engineering, 56, pp. 538-543, (2013)
[8]  
Ramos J.C., Beiza M., Gastelurrutia J., Rivas A., Anton R., Larraona G.S., de Miguel I., Numerical Modelling of the Natural Ventilation of Underground Transformer Substations, Applied Thermal Engineering, 51, pp. 852-863, (2013)
[9]  
Schlabbach J.
[10]  
Smolka J., CFD-based 3-D Optimization of the Mutual Coil Configuration for the Effective Cooling of an Electrical Transformer, Applied Thermal Engineering, 50, pp. 124-133, (2013)