Biomechanical simulation of segmented intrusion of a mandibular canine using Robot Orthodontic Measurement & Simulation System (ROSS)

被引:0
|
作者
Sabbagh, Hisham [1 ]
Dotzer, Benedikt [1 ]
Baumert, Uwe [1 ]
Hoetzel, Linus [1 ]
Seidel, Corinna Lesley [1 ]
Wichelhaus, Andrea [1 ]
机构
[1] LMU Univ Hosp, Dept Orthodont & Dentofacial Orthoped, Goethes Str 70, Munich, Germany
关键词
Biomechanics; Orthodontics; 3D measurement; Force-control; Robotics; Segmented intrusion; Segmented arch mechanics; MAXILLARY CENTRAL INCISOR; OVERBITE CORRECTION; PURE INTRUSION; TOOTH MOVEMENT; ARCH; MECHANICS; ROTATION; SKELETAL; CENTERS; TEETH;
D O I
10.1016/j.jmbbm.2024.106720
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Aim of this study was to investigate the forces and moments during segmented intrusion of a mandibular canine using Cantilever-Intrusion-Springs (CIS). Methods: Three different CIS modifications were investigated using a robotic biomechanical simulation system: unmodified CIS (#1, control), CIS with a lingual directed 6 degrees toe-in bend (#2), and CIS with an additional 20 degrees twist bend (#3). Tooth movement was simulated by the apparative robotic stand, controlled by a force-control algorithm, recording the acting forces and moments with a force-torque sensor. Statistical analysis was performed using Shapiro-Wilk, Kolmogorov-Smirnov, Kruskal-Wallis ANOVA and post hoc tests with Bonferroni correction (alpha = 0.05). Results: The initial intrusive force, which was uniformly generated by a 35 degrees Tip-Back bend, decreased significantly (p < 0.05) from 0.31 N in group (#1) to 0.28 N in group (#3). Vestibular crown tipping reduced significantly (p < 0.05) from 2.11 degrees in group (#1) and 1.72 degrees in group (#2) to 0.05 degrees in group (#3). Matching to that the direction of orovestibular force significantly (p <0.05) shifted from 0.15 N to vestibular in group (#1) to 0.51 N to oral in group (#3) and the orovestibular tipping moment decreased also significantly (p <0.05) from 4.63 Nmm to vestibular in group (#1) to 3.56 Nmm in group (#2) and reversed to 1.20 Nmm to oral in group (#3). Apart from that the orovestibular displacement changed significantly (p < 0.05) from 0.66 mm in buccal direction in group (#1) to 0.29 mm orally in group (#2) and 1.49 mm in oral direction as well in group (#3). Significance: None of the modifications studied achieved pure mandibular canine intrusion without collateral effects. The significant lingual displacement caused by modification (#3) is, not least from an aesthetic perspective, considered much more severe than a slight tipping of the canine. Consequently, modification (#2) can be recommended for clinical application based on the biomechanical findings.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Investigation of Forces and Moments during Orthodontic Tooth Intrusion Using Robot Orthodontic Measurement and Simulation System (ROSS)
    Seidel, Corinna L.
    Lipp, Julian
    Dotzer, Benedikt
    Janjic Rankovic, Mila
    Mertmann, Matthias
    Wichelhaus, Andrea
    Sabbagh, Hisham
    BIOENGINEERING-BASEL, 2023, 10 (12):
  • [2] Biomechanical simulation of forces and moments of initial orthodontic tooth movement in dependence on the used archwire system by ROSS (Robot Orthodontic Measurement & Simulation System)
    Dotzer, Benedikt
    Stocker, Thomas
    Wichelhaus, Andrea
    Rankovic, Mila Janjic
    Sabbagh, Hisham
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 144
  • [3] APPLICATION OF THE ORTHODONTIC MEASUREMENT AND SIMULATION SYSTEM (OMSS) IN ORTHODONTICS
    DRESCHER, D
    BOURAUEL, C
    THIER, M
    EUROPEAN JOURNAL OF ORTHODONTICS, 1991, 13 (03) : 169 - 178
  • [4] Design and Implementation of Software Simulation System for Dental Orthodontic Robot
    Zhou, Chuanhong
    Pan, Shiyu
    Zhou, Tao
    2019 3RD INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE APPLICATIONS AND TECHNOLOGIES (AIAAT 2019), 2019, 646
  • [5] Force-Controlled Biomechanical Simulation of Orthodontic Tooth Movement with Torque Archwires Using HOSEA (Hexapod for Orthodontic Simulation, Evaluation and Analysis)
    Haas, Ellen
    Schmid, Andreas
    Stocker, Thomas
    Wichelhaus, Andrea
    Sabbagh, Hisham
    BIOENGINEERING-BASEL, 2023, 10 (09):
  • [6] Dynamic measurement of orthodontic force using a tooth movement simulation system based on a wax model
    Wu, Jianlei
    Liu, Yunfeng
    Wang, Dongcai
    Huang, Senda
    Zhang, Jianxing
    Chen, Jie
    Dong, Xingtao
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (03) : 457 - 466
  • [7] Interceptive orthodontic management of mandibular lateral incisor-canine transposition using simplified and efficient biomechanical approach: A case report
    Singh, Harpreet
    Mittal, Tanmay
    Sharma, Poonam
    Kapoor, Pranav
    Maurya, Raj Kumar
    Rastogi, Shweta
    INTERNATIONAL ORTHODONTICS, 2022, 20 (04)
  • [8] Simulation of Walking Support System Using Humanoid Robot
    Omer, Aiman Musa M.
    Kondo, Hideki
    Lim, Hun-ok
    Takanishi, Atsuo
    2008 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION, 2008, : 48 - +
  • [9] MODELLING AND SIMULATION OF ROBOT SYSTEM USING MATLAB AND SIMULINK
    Damic, Vjekoslav
    Cohodar, Maida
    Kulenovic, Malik
    ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1247 - 1248
  • [10] Dynamic simulation system using DOF picking robot
    Liu, Xiaojun
    Open Automation and Control Systems Journal, 2015, 7 (01): : 1746 - 1751