Ground fault protection for generator stator windings with inductance compensating based on injecting signal

被引:0
|
作者
Zeng, Xiang-Jun [1 ]
Yin, Xiang-Gen [1 ]
Chen, De-Shu [1 ]
Zhang, Zhe [1 ]
机构
[1] Dept. of Elec. Power Eng., Huazhong Univ. of Sci. and Technol., Wuhan 430074, China
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2000年 / 20卷 / 11期
关键词
Electric windings - Protection - Sensitivity analysis - Signal processing - Stators;
D O I
暂无
中图分类号
学科分类号
摘要
Traditional methods for detecting single-phase-to-ground faults in generator stator windings based on injecting signal have poor performance in high resistor grounding fault due to the effect of the capacitance of generator stator windings. It can be improved by using an inductance, with parallel connection on the neutral grounding resistor at the second side of distribution transformer to compensate the capacitance of generator stator windings. By selecting a suitable frequency of injection signal, the grounding fault protection can be realized by measuring the grounding resistance of fault point or injecting signal power factor. The simulation results show that it can detect very high impedance ground fault.
引用
收藏
页码:51 / 55
相关论文
共 50 条
  • [41] Differential Protection Analisys For Detection Of Ground Faults On the Generator Stator
    Fernandez Alvarez, Christian H.
    Pinos Veintimilla, Carlota M.
    Quizhpi Palomeque, Flavio A.
    2022 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2022,
  • [42] Intermittent Line-to-Ground Faults in Generator Stator Windings and Consequences on Neutral Grounding
    Braun, Dieter
    Koeppl, Georg S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 876 - 881
  • [43] Analysis on stator ground fault protection trip caused by ground fault in voltage transformer circuit
    Wang, X. (wangxin_brave@yahoo.com.cn), 2013, Automation of Electric Power Systems Press (37):
  • [44] A novel 20Hz power injection protection scheme for stator ground fault of pumped storage generator
    Zhu, Zheng
    Lu, Yuping
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1911 - 1915
  • [45] Stator single-line-to-ground fault protection for powerformers based on HSGC and CNN
    Liu, Xiaohan
    Wang, Yuanyuan
    Luo, Xiaomin
    Cao, Chengjun
    Li, Wei
    Wang, Buming
    Wang, Jiabao
    Wang, Yin
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [46] Study on stator earth fault protection of generator connected as expanding unit
    Chen, Jun
    Shen, Quanrong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2007, 31 (24): : 86 - 89
  • [47] Single-phase grounded fault protection schemes of generator stator based on orthonormal wavelet
    Tai, Nengling
    Yin, Xianggen
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2001, 25 (01): : 34 - 37
  • [48] Improvements in ground-fault protection of unit-connected generator stator winding using laboratory test environment
    Zielichowski, Mieczyslaw
    Szlezak, Tomasz
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (09) : 1635 - 1639
  • [49] Studies on the Stator Single-Phase-to-Ground Fault Protection for a High-Voltage Cable-Wound Generator
    Wang, Yuan Yuan
    Zeng, Xiang Jun
    Jian, Jin Bao
    Dong, Zhao Yang
    Li, Ze Wen
    Huang, Yue
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (02) : 344 - 352
  • [50] Faults detection in stator windings of induction motors based on signal injection
    Otero, M.
    de la Barrera, P. M.
    Bossio, G. R.
    Leidhold, R.
    Tyshakin, O.
    2018 IEEE BIENNIAL CONGRESS OF ARGENTINA (ARGENCON), 2018,