Ground fault protection for generator stator windings with inductance compensating based on injecting signal

被引:0
|
作者
Zeng, Xiang-Jun [1 ]
Yin, Xiang-Gen [1 ]
Chen, De-Shu [1 ]
Zhang, Zhe [1 ]
机构
[1] Dept. of Elec. Power Eng., Huazhong Univ. of Sci. and Technol., Wuhan 430074, China
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2000年 / 20卷 / 11期
关键词
Electric windings - Protection - Sensitivity analysis - Signal processing - Stators;
D O I
暂无
中图分类号
学科分类号
摘要
Traditional methods for detecting single-phase-to-ground faults in generator stator windings based on injecting signal have poor performance in high resistor grounding fault due to the effect of the capacitance of generator stator windings. It can be improved by using an inductance, with parallel connection on the neutral grounding resistor at the second side of distribution transformer to compensate the capacitance of generator stator windings. By selecting a suitable frequency of injection signal, the grounding fault protection can be realized by measuring the grounding resistance of fault point or injecting signal power factor. The simulation results show that it can detect very high impedance ground fault.
引用
收藏
页码:51 / 55
相关论文
共 50 条
  • [21] Injecting square wave voltage type ground fault protection for generator rotor based on redundancy sampling and calculation
    Li, Zhe
    Lu, Jun
    Qiu, Xinhong
    Ji, Xuejun
    Liu, Hongbo
    Wang, Yu
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (19): : 105 - 107
  • [22] Generator stator windings ground fault diagnosis for generator-grid directly connected system of floating nuclear power plant
    Wang, Yikai
    Yin, Xianggen
    Qiao, Jian
    Tan, Liming
    Xu, Wen
    Li, Wei
    ENERGY REPORTS, 2021, 7 : 460 - 469
  • [23] Analysis of operating conditions of ground-fault protection schemes for generator stator winding
    Zielichowski, M
    Fulczyk, M
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (01) : 57 - 62
  • [24] Adaptive 100% Injection-Based Generator Stator Ground Fault Protection With Real-Time Fault Location Capability
    Safari-Shad, Nader
    Franklin, Russ
    Negahdari, Amir
    Toliyat, Hamid A.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (05) : 2364 - 2372
  • [25] Third Harmonic Differential Over Current Relay Based Protection System for Stator Ground Fault in Synchronous Generator
    Chowdhury, Md. Asif
    Reza, Kazi Taimur
    Alam, Md. Didarul
    Basher, Enamul
    2016 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2016, : 606 - 609
  • [26] Protection schemes and sensitivity analysis for huge sized hydro-generator stator ground fault
    Tai, Nengling
    Yin, Xianggen
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2000, 24 (07): : 41 - 45
  • [27] Understanding Generator Stator Ground Faults and Their Protection Schemes
    Klingerman, Nathan
    Finney, Dale
    Samineni, Satish
    Fischer, Normann
    Haas, Derrick
    2016 69TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2016,
  • [28] Study of self-adaptive generator stator ground fault protection based on 20 Hz electric source injection
    Yao, Qinglin
    Zhao, Bin
    Guo, Baofu
    Chen, Hailong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2009, 33 (22): : 71 - 74
  • [29] Performance Verification of an Adaptive 100% Injection-Based Stator Ground Fault Protection Using a Large MVA Generator
    Safari-Shad, Nader
    Franklin, Russ
    2019 72ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2019,
  • [30] Analyzing stator windings main protection of generator for Qingjiang Shuibuya hydropower station
    Hubei Qingjiang Hydropower Development Ltd Co., Yichang 443000, China
    Dianli Xitong Baohu yu Kongzhi, 2009, 20 (104-107): : 104 - 107