In order to analyze the fire behavior of the two-way concrete slab with out-of-plane restraints on corners under constant loads, one fire test which includes the wireless temperature measurement and infrared detection was conducted to obtain the temperature field along the depth, the reinforcement temperature, the out-of-plane and in-plane deflection, crack and the corners' out-of-plane restraint reaction. The test results also were compared with the relevant tests at home and abroad. Results indicate that the wireless measurement could get high-accuracy results with easy use, and the infrared detection technology can have a real-time observation on the slabs' cracks. The cracking pattern and deflection of the slab with out-of-plane restraints on the corners is clearly different from those of the simply support slabs, and arc-shaped cracks easily occurred near to slabs' corners. The corners' restraint degree has a considerable effect on the arc-shaped crack distribution and development of the slabs' corners. © 2017, Editorial Office of Journal of Building Structures. All right reserved.
引用
收藏
页码:125 / 132
页数:7
相关论文
共 15 条
[1]  
Yang Z., Dong Y., Lv J., Et al., Experimental study of two-way reinforced concrete slab subjected to fire in a whole structure, Journal of Building Structures, 33, 9, pp. 96-103, (2012)
[2]  
Wang Y., Dong Y.L., Li B., Zhou G.C., A fire test on continuous reinforced concrete slabs in a full-scale multi-story steel-framed building, Fire Safety Journal, 61, 5, pp. 232-242, (2013)
[3]  
Wang B., Dong Y., Experimental research of four-edge simple support two-way reinforced concrete slab under fire, Journal of Building Structures, 30, 6, pp. 23-33, (2009)
[4]  
Lim L., Wade C., Experimental Fire Tests of Two-Way Concrete Slabs, pp. 24-53, (2002)
[5]  
Dong Y., Zhu C., Limit load carrying capacity of two-way slabs with two edges clamped and two edges simply supported in fire, Journal of Structural Engineering, 137, 10, pp. 1182-1192, (2011)
[6]  
Wang B., Design Manual of Industrial Furnace, (2010)
[7]  
Standard for test method of concrete structures: GB/T 50152-2012, (2012)
[8]  
Fire-resistance tests: elements of building: GB/T 9978-2008, (2008)
[9]  
Li G., Guo S., Zhou H., Modeling of membrane action in floor slabs subjected to fire, Engineering Structures, 29, 6, pp. 880-887, (2007)
[10]  
Bailey C.G., Toh W.S., Small-scale concrete slab tests at ambient and elevated temperatures, Engineering Structures, 29, 10, pp. 2775-2791, (2007)