Blackbody radiation simulated based on Monte carlo method

被引:0
作者
Science and Technology on Electronic Test and Measurement Laboratory, The 41st Institute of China Electronics Technology Group Corporation, Qingdao [1 ]
Shandong
266555, China
机构
[1] Science and Technology on Electronic Test and Measurement Laboratory, The 41st Institute of China Electronics Technology Group Corporation, Qingdao, 266555, Shandong
来源
Guangxue Xuebao |
关键词
Effective emissivity; Infrared radiation; Measurement; Monte Carlo method;
D O I
10.3788/AOS201333.s212004
中图分类号
学科分类号
摘要
The infrared radiant characteristics of blackbody are researched and the effective emissivity of blackbody is calculated based on Monte Carlo method. The infrared radiant random model of blackbody is established based on the Monte Carlo method. A large amount of random infrared radiations are sampled and tracked. The approximate value of blackbody effective emissivity can be obtained by counting the radiant properties of blackbody. The results of simulation experiments and theory analysis demonstrate that proposed method can resolve the calculational defect of blackbody radiation by utilizing the integral algorithm, and the computational complexity is reduced effectively due to the new method, which removes the integral algorithm of current Monte Carlo method. The effective emissivity gained by simulation is basal coincident with the actual effective emissivity of blackbody. Theory analysis and simulation experiments show that the new method is reasonable and efficient.
引用
收藏
相关论文
共 12 条
  • [1] Chen H., Zhang L., Zou P., Et al., 400~900 nm spectral irradiance of cryogenic radio meter based irradiance standard lamp using system level calibration method, 30, 11, pp. 3349-3353, (2010)
  • [2] Liu Y.J., Xu G., Ojanen M., Et al., Spectral irradiance comparison using a multi-wavelength filter radiometer, Metrologia, 46, S1, pp. 81-85, (2009)
  • [3] Jin M., Bai M., Miao J., Emissivity study of the array shaped blackbody in the microwave band, 61, 16, (2012)
  • [4] Xie X., Zhang W., Zhi X., Et al., Scene based assessment method for nonuniformity of infrared focal plane array, 32, 6, (2012)
  • [5] Du B., Zhang Y., Li Y., Algorithm for selecting blackbody radiation source of infrared target simulator, Optics & Optoelectronic Technology, 10, 3, pp. 71-73, (2012)
  • [6] Zhang X., Research of heat pipe blackbody designing and assessing technology, Metrology & Measurement Technology, 32, 4, pp. 30-32, (2012)
  • [7] Song X., Discussion of effective emissivity calibration for blackbody furnace, China Measurement & Test, 35, 6, pp. 28-29, (2009)
  • [8] Liu D., Duan Y., Yang Z., Integrated effective emissivity computation for non-isothermal non-axisymmetric cavities, Chin Opt Lett, 11, 2, (2013)
  • [9] Zhang H., Dai J., Design and evaluation of a blackbody furnace of heat-pipe surface source with large aperture, Journal of China Jiliang University, 17, 2, pp. 95-98, (2006)
  • [10] Liu B., Surface Blackbody Radiation Characteristics Analysis and Design, pp. 14-15, (2011)