Hygroscopicity of atmospheric sub-micrometer particles in various environments in China

被引:0
|
作者
Wang, Yu [1 ]
Wu, Zhi-Jun [1 ]
Hu, Min [1 ]
机构
[1] State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing,100871, China
关键词
Chemical compositions - Effective hygroscopic parameters - Hygroscopicity-tandem differential mobility analyzers - Mass size distribution - Mode distribution - Particle hygroscopicity - Size-resolved particles - Submicrometer particle;
D O I
暂无
中图分类号
学科分类号
摘要
In the past several years, the measurements of particle hygroscopicity were deployed using H-TDMA (Hygroscopicity-Tandem Differential Mobility Analyzer). This study compiled the outcomes in our group and published results to summarize the hygroscopicity of the sub-micrometer particles in various environments in China. The κ values in the urban areas were around 0.1~0.3. In rural areas, the κ values ranged from 0.15 to 0.4, which were slightly higher than the urban one. The κ values at a mountain site (118.11°E, 30.07°N) and a near-coastal site (114.17°E, 22.28°N) were 0.2~0.3 and 0.2~0.4 respectively. Except for the observation in a rural site of Beijing during wintertime, the particle hygroscopicity increased with increasing particle size in other rural and urban sites. No significant dependency between the hygroscopicity and particle size in the mountain and coastal areas. Typically, particle hygroscopicity showed 2~3 modes distribution, indicating an external mixing state of atmospheric particles. However, high frequency of a single mode (hydrophilic mode) was observed in the mountain site. The growth factor (GF) smoothly enhanced with increasing relative humidity (RH) in the atmosphere of Beijing and Hangzhou, without showing a delinquent behavior. The closure studies between particle hygroscopicity and chemical composition showed that the hygroscopicity can be well predicted using size-resolved particle chemical composition. The precise detections of particle density and hygroscopicity of organics, and the mass size distribution of black carbon are still needed for the improvement of closure study. © 2017, Editorial Board of China Environmental Science. All right reserved.
引用
收藏
页码:1601 / 1609
相关论文
共 50 条
  • [11] A method for the determination of sub-micrometer particle lung deposition in indoor environments
    Pagels, J.
    Falk, R.
    Gudmundsson, A.
    Bohgard, M.
    1600, Elsevier Ltd (31):
  • [12] Detecting pH of Sub-Micrometer Aerosol Particles Using Fluorescent Probes
    Li, Weihan
    Kuwata, Mikinori
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (23) : 8701 - 8707
  • [13] Deformation mechanism of polystyrene toughened with sub-micrometer monodisperse rubber particles
    Gao, Guanghui
    Zhang, Jingshu
    Yang, Haidong
    Zhou, Chao
    Zhang, Huixuan
    POLYMER INTERNATIONAL, 2006, 55 (11) : 1215 - 1221
  • [14] NanoSIMS measurements of sub-micrometer particles using the local thresholding technique
    Hao, Jialong
    Yang, Wei
    Huang, Wenjuan
    Xu, Yuchen
    Lin, Yangting
    Changela, Hitesh
    SURFACE AND INTERFACE ANALYSIS, 2020, 52 (05) : 234 - 239
  • [15] Wood pulp based filters for removal of sub-micrometer aerosol particles
    Mao, Jingliang
    Grgic, Biljana
    Finlay, Warren H.
    Kadla, John F.
    Kerekes, Richard J.
    NORDIC PULP & PAPER RESEARCH JOURNAL, 2008, 23 (04) : 420 - 425
  • [16] Effective multiple optical trapping of sub-micrometer particles with petal beams
    Shahabadi, V
    Madadi, E.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2020, 37 (12) : 3665 - 3671
  • [17] Determination of the refractive index of particles in the clay and sub-micrometer size range
    Weidler, Peter G.
    Friedrich, Frank
    AMERICAN MINERALOGIST, 2007, 92 (07) : 1130 - 1132
  • [18] Stable TiOx sub-micrometer chanells
    Scarminio, J
    Rigon, EL
    Cescato, L
    Gorenstein, A
    MICROFABRICATED SYSTEMS AND MEMS VI, PROCEEDINGS, 2002, 2002 (06): : 130 - 135
  • [19] Sub-micrometer particulate air pollution and cardiovascular mortality in Beijing, China
    Breitner, Susanne
    Liu, Liqun
    Cyrys, Josef
    Brueske, Irene
    Franck, Ulrich
    Schlink, Uwe
    Leitte, Arne Marian
    Herbarth, Olf
    Wiedensohler, Alfred
    Wehner, Birgit
    Hu, Min
    Pan, Xiao-Chuan
    Wichmann, H-Erich
    Peters, Annette
    SCIENCE OF THE TOTAL ENVIRONMENT, 2011, 409 (24) : 5196 - 5204
  • [20] Preparation of sub-micrometer LnPO4 particles (Ln = La, Ce)
    Feldmann, C
    Jungk, HO
    JOURNAL OF MATERIALS SCIENCE, 2002, 37 (15) : 3251 - 3254