Partial discharge inception voltage and location of partial discharge source in ribbon type enameled wire

被引:0
作者
Nakaya, Hirotaka [1 ]
Kozako, Masahiro [1 ]
Hikita, Masayuki [1 ]
Tomizawa, Keiichi [2 ]
Oya, Makoto [3 ]
Muto, Daisuke [3 ]
机构
[1] Kyushu Institute of Technology, 1-1, Sensui-cho, Tobata-ku, Kitakyushu
[2] Furukawa Magnet Wire Co., Ltd., 2-2-3, Marunouchi, Chiyoda-ku, Tokyo
[3] Furukawa Electric Co., Ltd., 2-2-3, Marunouchi, Chiyoda-ku, Tokyo
关键词
Identification of partial discharge occurrence location; Inverter surge; Partial discharge; Partial discharge inception voltage; Ribbon type enameled wire;
D O I
10.1541/ieejfms.135.107
中图分类号
学科分类号
摘要
As technology of inverter-fed motors progresses in recent years, means of protection against inverter surge for the motor windings have been developed. It is strongly required for windings used in electric vehicles and hybrid electric vehicles to have excellent insulations properties together with high heat resistance, especially high partial discharge inception voltage (PDIV). This paper deals with PDIV of ribbon-type enameled wire which is fabricated to increase space factor in the motor windings compared with the conventional enamel wire. © 2015 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:107 / 112
页数:5
相关论文
共 9 条
  • [1] Cavallini A., Fabiani D., Montanari G.C., Power Electronics and Electrical Insulation Systems - Part 3: Diagnostic Properties, IEEE Electrical Insulation Magazine, pp. 30-40, (2010)
  • [2] Kikuchi H., Hatano H., Inverter Surge Resistant Enameled Wire with Nanocomposite Insulating Material, IEEE Trans. Dielectr. [[Ampi]]amp
  • [3] Electr. Insul., 19, 1, pp. 99-106, (2012)
  • [4] Hayakawa N., Morikawa M., Okubo H., Partial Discharge Inception and Propagation Characteristics of Magnet Wire for Inverter-fed Motor under Surge Voltage Application, IEEE Trans. Dielectr. [[Ampi]]amp
  • [5] Electr. Insul., 14, 1, pp. 39-45, (2007)
  • [6] Okubo H., Hayakawa N., Montanari G.C., Technical Development on Partial Discharge Measurement and Electrical Insulation Techniques for Low Voltage Motors Driven by Voltage Inverters, IEEE Trans. Dielectr. [[Ampi]]amp
  • [7] Electr. Insul., 14, 6, pp. 1516-1530, (2007)
  • [8] Koyanagi T., Ushirone S., Fukunaga K., Kimura K., Hikita M., The PDIV characteristic of the twisted pair using electric field calculation, The Papers of Joint Technical Meeting on Electric Discharge / Dielectric and an Insulating Material /High-Voltage IEE Japan, pp. 7-12, (2006)
  • [9] Dakin T.W., Luxa G., Oppermann G., Vigreux J., Wind G., Winkelnkemer H., Breakdown of Gases in Uniform Fields - Paschen Curves for Nitrogen, Air and Sulfer Hexafluoride, Electra, 32, pp. 61-82, (1974)