An alternative field switching ion gate for ESI-ion mobility spectrometry

被引:10
作者
Zühlke M. [1 ]
Zenichowski K. [1 ]
Riebe D. [1 ]
Beitz T. [1 ]
Löhmannsröben H.-G. [1 ]
机构
[1] Physical Chemistry, University of Potsdam, Karl-Liebknecht-Str. 24-25, Potsdam
来源
Zühlke, M. (mzuehlke@uni-potsdam.de) | 1600年 / Springer Verlag卷 / 20期
关键词
Electrospray ionization; Field switching ion gate; Ion mobility spectrometry; Peptide; Resolving power;
D O I
10.1007/s12127-017-0222-y
中图分类号
学科分类号
摘要
In electrospray ionization (ESI)-ion mobility spectrometry, continuously generated ions must be desolvated in a first tube before short ion pulses are introduced into a second (drift) tube. Both tubes are separated by an ion-gate. The resolving power of the resulting drift time spectrum is strongly influenced by the design of the ion gate. In the case of the Bradbury-Nielsen gates typically used, an orthogonal field between oppositely charged, parallel wires blocks ions from entering the drift tube. However, the blocking field also distorts the entering ion cloud. One alternative, which eliminates these effects and therefore enables a potentially higher resolving power, is already known for spectrometers with small ionization volumes, where ions are formed between two electrodes and subsequently transferred into the drift tube by a high voltage pulse. Based on this setup, we introduce an alternative ion gate design for liquid samples, named field switching ion gate (FSIG). The continuous flow of ions generated by ESI is desolvated in the first tube and introduced into the space between two electrodes (repeller and transfer electrodes). A third (blocking) electrode prevents the movement of ions into the drift tube in the closed state. Ions are transferred during the open state by pulsing the voltages of the repeller and blocking electrodes. First results demonstrate an increase of the resolving power by 100% without intensity losses and further changes in the spectrometer setup. The parameters of the FSIG, such as electrode voltages and pulse width, are characterized allowing the optimization of the spectrometer’s resolving power. © 2017, Springer-Verlag GmbH Germany.
引用
收藏
页码:67 / 73
页数:6
相关论文
共 16 条
[1]  
Cottingham K., Ion mobility spectrometry rediscovered, Anal Chem, 75, pp. 435 A-439 A, (2003)
[2]  
Kirk A.T., Zimmermann S., An analytical model for the optimum drift voltage of drift tube ion mobility spectrometers with respect to resolving power and detection limits, Int J Ion Mobil Spectrom, 18, pp. 129-135, (2015)
[3]  
Tabrizchi M., Temperature effects on resolution in ion mobility spectrometry, Talanta, 62, pp. 65-70, (2004)
[4]  
Siems W.F., Wu C., Tarver E.E., Et al., Measuring the resolving power of ion mobility spectrometers, Anal Chem, 66, pp. 4195-4201, (1994)
[5]  
Dugourd P., Hudgins R.R., Clemmer D.E., Jarrold M.F., High-resolution ion mobility measurements, Rev Sci Instrum, 68, pp. 1122-1129, (1997)
[6]  
Bradbury N.E., Nielsen R.A., Absolute values of the electron mobility in hydrogen, Phys Rev, 49, pp. 388-393, (1936)
[7]  
Tyndall A.M., The mobility of positive ions in gases, (1938)
[8]  
Kirk A.T., Zimmermann S., Bradbury-Nielsen vs. field switching shutters for high resolution drift tube ion mobility spectrometers, Int J Ion Mobil Spectrom, 17, pp. 131-137, (2014)
[9]  
Kirk A.T., Allers M., Cochems P., Et al., A compact high resolution ion mobility spectrometer for fast trace gas analysis, Analyst, 138, pp. 5200-5207, (2013)
[10]  
Kirk A.T., Zimmermann S., Pushing a compact 15cm long ultra-high resolution drift tube ion mobility spectrometer with R = 250 to R = 425 using peak deconvolution, Int J Ion Mobil Spectrom, 18, pp. 17-22, (2015)