Critical factors and their impact on bioelectrical impedance analysis in children: a review

被引:46
作者
Brantlov S. [1 ]
Ward L.C. [2 ]
Jødal L. [3 ]
Rittig S. [4 ]
Lange A. [4 ]
机构
[1] Department of Procurement & Clinical Engineering, Aarhus University Hospital, Aarhus
[2] School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane
[3] Department of Nuclear Medicine, Aalborg University Hospital, Aalborg
[4] Department of Paediatrics, Aarhus University Hospital, Aarhus
关键词
Bioelectrical impedance analysis; children; guideline; review; standardisation;
D O I
10.1080/03091902.2016.1209590
中图分类号
学科分类号
摘要
Several guidelines for bioelectrical impedance analysis (BIA) have been prepared for adults, but not for children. For that reason, there is a pressing need to develop a consensus set of guidelines to facilitate standardisation of BIA in this important group. This review provides an introduction to BIA, highlights critical factors that may impact on BIA and identifies areas where there is a need for further research in order to increase the quality of impedance measurements and prediction of body composition in children. Although the results of this review highlights a lack of studies in children to provide definitive BIA guidelines, the technique has, however, still proven valuable for body composition assessment in ill and healthy children. To fill the gaps in our knowledge, future studies should focus on methodological issues, particularly with regard to hydration, voiding, clothing, skin preparation and body position. The review may advantageously be used as a checklist in the planning of future studies. Finally, this review forms the basis for the development of guidelines for BIA assessment in this particular group; a task appropriately to be undertaken by scientific societies within the field. © 2016 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:22 / 35
页数:13
相关论文
共 104 条
  • [51] Gonzalez-Correa C.H., Caicedo-Eraso J.C., Bioelectrical impedance analysis (BIA): a proposal for standardisation of the classical method in adults, J Phys Conf Ser, 407, (2012)
  • [52] Liang M.T., Norris S., Effects of skin blood flow and temperature on bioelectric impedance after exercise, Med Sci Sports Exerc, 25, pp. 1231-1239, (1993)
  • [53] Nakadomo F., Tanaka K., Yokoyama T., Et al., Effects of different electrodes on bioelectrical impedance values, Ann Physiol Anthropol, 9, pp. 41-45, (1990)
  • [54] Caicedo-Eraso J.C., Gonzalez-Correa C.H., Gonzalez-Correa C.A., Use of electrocardiogram (ECG) electrodes for bioelectrical impedance analysis (BIA), J Phys Conf Ser, 407, (2012)
  • [55] Buendia R., Bogonez-Franco P., Nescolarde L., Et al., Influence of electrode mismatch on Cole parameter estimation from total right side electrical bioimpedance spectroscopy measurements, Med Eng Phys, 34, pp. 1024-1028, (2012)
  • [56] Bogonez-Franco P., Nescolarde L., Bragos R., Et al., Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch, Physiol Meas, 30, pp. 573-587, (2009)
  • [57] Piccoli A., Fanos V., Peruzzi L., Et al., Reference values of the bioelectrical impedance vector in neonates in the first week after birth, Nutrition, 18, pp. 383-387, (2002)
  • [58] Raghavan C.V., Super D.M., Chatburn R.L., Et al., Estimation of total body water in very-low-birth-weight infants by using anthropometry with and without bioelectrical impedance and H2[(18)O], Am J Clin Nutr, 68, pp. 668-674, (1998)
  • [59] Tang W., Ridout D., Modi N., Assessment of total body water using bioelectrical impedance analysis in neonates receiving intensive care, . Arch Dis Child Fetal Neonatal Ed, 77, pp. F123-F126, (1997)
  • [60] Oldroyd B., Truscott J.G., Holland P.C., Et al., Multi-frequency bio-electrical impedance: precision in normal children, Appl Radiat Isot, 49, pp. 529-530, (1998)