Influence of rotor windings inter-turn short circuit fault on electric machine shaft voltage

被引:0
|
作者
Li, He-Ming [1 ]
Wu, Yu-Cai [1 ]
Li, Yong-Gang [1 ]
机构
[1] School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, Hebei Province, China
关键词
Winding - Magnetic circuits - Timing circuits;
D O I
暂无
中图分类号
学科分类号
摘要
The relations between rotor windings inter-turn short circuit fault and electric machine shaft voltage was researched. Air-gap conductance method was adopted to analyze electrical machine air-gap magnetic field, and the air gap permeance model was built by taking stator slot effect into consideration. When inter-turn short circuit fault happens, the fault characteristic frequency corresponding to the number of stator slots is predicted to appear in shaft voltage signal, which can be used as the criterion of rotor windings inter-turn short circuit fault. The simulation experiment on fault simulation unit verified the feasibility of the method. © Chin. Soc. for Elec. Eng.
引用
收藏
页码:96 / 100
相关论文
共 50 条
  • [41] Early warning of inter-turn short circuit fault in excitation windings of synchronous generator based on deep belief network
    Li J.
    Chen Y.
    Li S.
    1600, Electric Power Automation Equipment Press (41): : 153 - 158
  • [42] Inter-turn Short Circuit Fault Detection in Permanent Magnet Synchronous Motors Based on Reference Voltage
    Ahn, Giljun
    Lee, Junmin
    Park, Chan Hee
    Youn, Myeongbaek
    Youn, Byeng D.
    PROCEEDINGS OF THE 2019 IEEE 12TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2019, : 245 - 250
  • [43] The steady-state fault characteristics of a large hydro-generator with inter-turn short circuit of field windings
    Hao, Liangliang
    Sun, Yuguang
    Qiu, Arui
    Wang, Xiangheng
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (04): : 40 - 45
  • [44] Rotor winding inter-turn short-circuit fault detection in wound rotor induction motors using Wing Technique
    Ujwala Vikas Dongare
    Bhimrao Sitaram Umre
    Makarand Sudhakar Ballal
    Journal of Power Electronics, 2022, 22 : 614 - 628
  • [45] EFFECT OF STATIC ECCENTRICITY AND STATOR INTER-TURN SHORT CIRCUIT COMPOSITE FAULT ON ROTOR VIBRATION CHARACTERISTICS OF GENERATOR
    He, Yu-Ling
    Ke, Meng-Qiang
    Wang, Fa-Lin
    Tang, Gui-Ji
    Wan, Shu-Ting
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2015, 39 (04) : 767 - 781
  • [46] Fault feature extraction of rotor broken bar and stator winding inter-turn short circuit of asynchronous motors
    Liu, Chunyang
    Xu, Lijia
    Chen, Xinyuan
    2018 INTERNATIONAL SEMINAR ON COMPUTER SCIENCE AND ENGINEERING TECHNOLOGY (SCSET 2018), 2019, 1176
  • [47] Diagnosis of inter-turn short circuit fault in rotor winding of turbo generator using excitation step method
    Wu Y.-C.
    Wang Y.-X.
    Xu Q.-J.
    Xu J.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2017, 21 (09): : 22 - 30
  • [48] Rotor winding inter-turn short-circuit fault detection in wound rotor induction motors using Wing Technique
    Dongare, Ujwala Vikas
    Umre, Bhimrao Sitaram
    Ballal, Makarand Sudhakar
    JOURNAL OF POWER ELECTRONICS, 2022, 22 (04) : 614 - 628
  • [49] Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
    Zhang, Jiayuan
    Zhan, Wei
    Ehsani, Mehrdad
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (04) : 2267 - 2275
  • [50] Machine Learning for Inter-Turn Short-Circuit Fault Diagnosis in Permanent Magnet Synchronous Motors
    Shih, Kai-Jung
    Hsieh, Min-Fu
    Chen, Bo-Jia
    Huang, Shih-Feng
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (08)