Third order sliding mode observer-based approach for distributed optimal load frequency control

被引:31
作者
Rinaldi G. [1 ]
Cucuzzella M. [1 ]
Ferrara A. [1 ]
机构
[1] Dipartimento di Ingegneria Industriale e dell’Informazione, University of Pavia, Pavia
来源
IEEE Control Systems Letters | 2017年 / 1卷 / 02期
关键词
Observers for nonlinear systems; Power systems; Variable-structure/sliding-mode control;
D O I
10.1109/LCSYS.2017.2712564
中图分类号
学科分类号
摘要
In this letter, we propose a third order sliding mode observer-based approach for optimal load frequency control in power networks which are partitioned into control areas. We model each area by an equivalent generator including second-order turbine-governor dynamics. Assuming to measure only few state variables, we design two third order sliding mode observers for each control area to locally estimate the unmeasured states. We introduce also a distributed second order sliding mode control strategy, which makes use of the estimates coming from the observers and achieves both frequency regulation and minimization of generation costs. The simulation results confirm the validity of the proposed approach. © 2017 IEEE.
引用
收藏
页码:215 / 220
页数:5
相关论文
共 17 条
[1]  
Quaschning V., Understanding Renewable Energy Systems, (2016)
[2]  
Bevrani H., Robust Power System Frequency Control, (2009)
[3]  
Apostolopoulou D., Dominguez-Garcia A.D., Sauer P.W., An assessment of the impact of uncertainty on automatic generation control systems, IEEE Trans. Power Syst., 31, 4, pp. 2657-2665, (2016)
[4]  
Pandey S.K., Mohanty S.R., Kishor N., A literature survey on load–frequency control for conventional and distribution generation power systems, Renew. Sustain. Energy Rev., 25, pp. 318-334, (2013)
[5]  
Trip S., Burger M., De Persis C., An internal model approach to (optimal) frequency regulation in power grids with time-varying voltages, Automatica, 64, pp. 240-253, (2016)
[6]  
Trip S., De Persis C., Optimal frequency regulation in nonlinear structure preserving power networks including turbine dynamics: An incremental passivity approach, Proc. Amer. Control Conf., pp. 4132-4137, (2016)
[7]  
Cucuzzella M., Trip S., De Persis C., Ferrara A., Distributed second order sliding modes for optimal load frequency control, Proc. Amer. Control Conf., pp. 3451-3456, (2017)
[8]  
Howlader A.M., Et al., A minimal order observer based frequency control strategy for an integrated wind-battery-diesel power system, Energy, 46, 1, pp. 168-178, (2012)
[9]  
Jiang L., Wu Q.H., Wang J., Zhang C., Zhou X.X., Robust observer-based nonlinear control of multimachine power systems, IEE Proc. Gener. Transm. Distrib., 148, 6, pp. 623-631, (2001)
[10]  
Mellucci C., Menon P.P., Edwards C., Ferrara A., Load alteration fault detection and reconstruction in power networks modelled in semi-explicit differential algebraic equation form, Proc. Amer. Control Conf., pp. 5836-5841, (2015)