Advanced high speed MEMRECAM Ci 3 system is employed to make a experimental observation and study on moving condition and trajectories of solid particles, the stable and accumulating movement character of air phase, mechanism of performance abrupt by air-admission. Conclusions are drawn on the general movement character of air and solid phase and preliminary analysis has been carried out on its' moving mechanism. The solid particles move in a generally dispersed and a little trended way with relation to its shape and density. The behavior of air phase is relevant to inlet air fraction and the operating of the impeller, generally air phase separates and aggravates firstly on the outer side of the impeller, then accumulates and emerges hollow space in the center. When losing activity by air pocket, pump shakes fairly violently and may cause badly damage.
引用
收藏
页码:117 / 121
相关论文
共 50 条
  • [41] Influence of Blade Thickness on Solid-Liquid Two-Phase Flow and Impeller Wear in a Ceramic Centrifugal Slurry Pump
    Tao, Yi
    Bai, Yongming
    Wu, Yingchun
    PROCESSES, 2021, 9 (08)
  • [42] Experimental study on the whirling motion in the centrifugal blood pump with a magnetically coupled impeller
    Tsukiya, Tomonori
    Taenaka, Yoshiyuki
    Suzuki, Takayuki
    Horiguchi, Hironori
    Tsujimoto, Yoshinobu
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (07): : 1557 - 1563
  • [43] THE STUDY OF VARIOUS IMPELLER DESIGN FOR CENTRIFUGAL BLOOD PUMP USING COMPUTER METHOD
    Wannawat, Praemai
    Foojinphan, Nutchanant
    Khienwad, Thananya
    Naiyanetr, Phornphop
    2017 13TH IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING (BIOMED), 2017, : 247 - 253
  • [44] Study on transient cavitation performance of centrifugal pump based on the influence of rough impeller
    Gu, Jintong
    Sun, Huihui
    Yao, Yuan
    Chen, Qing
    Zeng, Yong
    Lu, Qian
    Fu, Shifeng
    PHYSICS OF FLUIDS, 2024, 36 (08)
  • [45] Cavitation characteristics and experimental study on the first stage impeller of centrifugal charging pump
    Zhu, Rong-Sheng
    Jiang, Xu-Song
    Fu, Qiang
    Long, Yun
    Wang, Xiu-Li
    Xi, Yi
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (10): : 1778 - 1785
  • [46] Experimental Study on a Prototype Centrifugal Pump with Open Impeller During Stopping Period
    Zhang, Yu-Liang
    Zhu, Zu-Chao
    Sheng, Yi-Ni
    Cui, Bao-Ling
    Li, Yi
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2016, 43 (01) : 18 - 27
  • [47] Erratum to: Experimental study on a centrifugal pump with an open impeller during startup period
    Yuliang Zhang
    Zuchao Zhu
    Yingzi Jin
    Baoling Cui
    Yi Li
    Huashu Dou
    Journal of Thermal Science, 2013, 22 : 196 - 196
  • [48] STUDY OF THE EFFECT OF IMPELLER SIDE CLEARANCE ON THE CENTRIFUGAL PUMP PERFORMANCE USING CFD
    Ayad, A. Farid
    Abdalla, H. M.
    Abou El-Azm, A.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 7A, 2016,
  • [49] A parametric study for improving the centrifugal pump impeller for use in viscous fluid pumping
    Shojaeefard, M. H.
    Tahani, M.
    Khalkhali, A.
    Ehghaghi, M. B.
    Fallah, H.
    Beglari, M.
    HEAT AND MASS TRANSFER, 2013, 49 (02) : 197 - 206
  • [50] A parametric study for improving the centrifugal pump impeller for use in viscous fluid pumping
    M. H. Shojaeefard
    M. Tahani
    A. Khalkhali
    M. B. Ehghaghi
    H. Fallah
    M. Beglari
    Heat and Mass Transfer, 2013, 49 : 197 - 206