This paper was originated by a problem that occurred in an injection-molding project. The mold design team reported that the machine produced excessive flash on the molded part, the Bulldog, of Kettering University's mascot. The investigation of the manufacturing process problem required the understanding of many factors that influenced excessive flashing. After discussion and input from the team, a simple four-factor full-factorial design with duplicate measurements was used for the experiment. The analysis revealed that factors A (pack pressure), C (injection speed), and D (screw RPM) and also the interactions AC and CD were significant. The settings for A, C, and D were obtained. The confirmation runs showed that the setting of A at low level (150 psi), C at low level (0.5 in./sec), and D at high level (200 rpm) produced Bulldogs with zero flash.
引用
收藏
页码:99 / 104
页数:5
相关论文
共 3 条
[1]  
MINITAB Release 13 Statistical Software, (2000)
[2]  
Montgomery D.C., Design and Analysis of Experiments. 5th Ed., pp. 265-269, (1997)
[3]  
Philip M., Injection Molding. Tool and Manufacturing Engineers Handbook, 8, pp. 61-62, (1996)