Performance analysis of adaptive non-communication relay protection operation under evolved fault condition

被引:0
|
作者
Shi, Shenxing [1 ]
Dong, Xinzhou [1 ]
Zhou, Shuangxi [1 ]
Bo, Z.Q. [2 ]
Caunce, B. [2 ]
机构
[1] Tsinghua Univ., Beijing 100084, China
[2] ALSTOM Protection and Control Co., Stafford, United Kingdom
来源
Dianli Xitong Zidonghua/Automation of Electric Power Systems | 2004年 / 28卷 / 11期
关键词
Adaptive noncommunication protection - Evolved fault;
D O I
暂无
中图分类号
学科分类号
摘要
(Edited Abstract)
引用
收藏
页码:6 / 8
相关论文
共 50 条
  • [1] Detection of high impedance fault using adaptive non-communication protection technique
    Bo, ZQ
    Dong, XZ
    Shi, SX
    Gan, Z
    Caunce, BRJ
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 376 - 381
  • [2] Adaptive non-communication protection scheme for power lines
    Bo, ZQ
    Doug, XZ
    Potts, S
    Weller, GC
    Chin, NF
    Montjean, D
    SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 137 - 140
  • [3] Adaptive non-communication protection for power lines BO scheme 3 - The accelerated operation approach
    Bo, ZQQ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (01) : 97 - 104
  • [4] Adaptive non-communication protection for power lines BO scheme 2 - The instant operation approach
    Bo, ZQQ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (01) : 92 - 96
  • [5] Adaptive non-communication protection for power lines BO scheme 1 - The delayed operation approach
    Bo, ZQQ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (01) : 85 - 91
  • [6] Research on non-communication protection of distribution lines based on fault components
    Bi, JG
    Dong, XZ
    Guo, YJ
    Bo, ZQ
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1151 - 1155
  • [7] Auto-reclosing adaptive to distribution line non-communication protection
    Liu, Kun
    Dong, Xinzhou
    Shi, Shenxing
    Wang, Bin
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2012, 52 (03): : 356 - 361
  • [8] Automatic switchover device adaptive to distribution line non-communication protection
    Electric Power Dispatching and Control Center of Guangdong Power Grid, Guangzhou 510600, China
    不详
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2013, 6 (147-151+162):
  • [9] Wavelet analysis based non-communication protection scheme for transmission lines
    Lin, X.N.
    Liu, P.
    Yang, C.M.
    Liu, S.M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2001, 21 (06): : 9 - 14
  • [10] Non-communication Protection for Single-Phase-to-Ground Fault Feeder in Neutral Non-Effectively Grounded Distribution System
    Jia, Qi
    Dong, Xinzhou
    Shi, Shenxing
    He, Xin
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,