Wireless Capsule Gastrointestinal Endoscopy: Direction-of-Arrival Estimation Based Localization Survey

被引:56
作者
Dey N. [1 ]
Ashour A.S. [2 ]
Shi F. [3 ]
Sherratt R.S. [4 ]
机构
[1] Department of Information Technology, Techno India College of Technology, Kolkata
[2] Department of Electronics and Electrical Communications Engineering, Faculty of Engineering, Tanta University, Tanta
[3] College of Information and Engineering, Wenzhou Medical University, Wenzhou
[4] Department of Biomedical Engineering, University of Reading, Reading
关键词
Direction-of-arrival estimation; endoscopy; endoscopy capsule; endoscopy electronics; endoscopy equipment; medical sensors; source localization; wireless video gastrointestinal (GI) endoscopy capsule;
D O I
10.1109/RBME.2017.2697950
中图分类号
学科分类号
摘要
One of the significant challenges in capsule endoscopy (CE) is to precisely determine the pathologies location. The localization process is primarily estimated using the received signal strength (RSS) from sensors in the capsule system through its movement in the gastrointestinal (GI) tract. Consequently, the wireless CE (WCE) system requires improvement to handle the lack of the capsule instantaneous localization information and to solve the relatively low transmission data rate challenges. Furthermore, the association among the capsule's transmitter position, capsule location, signal reduction, and the capsule direction should be assessed. These measurements deliver significant information for the instantaneous capsule localization systems based on time-of-arrival approach, phase difference of arrival, RSS, electromagnetic, direction of arrival (DOA), and video tracking approaches are developed to locate the WCE precisely. This review introduces the acquisition concept of the GI medical images using the endoscopy with a comprehensive description of the endoscopy system components. Capsule localization and tracking are considered to be the most important features of the WCE system, thus this paper emphasizes the most common localization systems generally, highlighting the DOA-based localization systems and discusses the required significant research challenges to be addressed. © 2017 IEEE.
引用
收藏
页码:2 / 11
页数:9
相关论文
共 73 条
[1]  
Mylonaki M., Fritscher-Ravens A., Swain P., Wireless capsule endoscopy: A comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding, Gut, 52, 8, pp. 1122-1126, (2003)
[2]  
Iddan G., Meron G., Glukhovsky A., Wireless capsule endoscopy, Nature, 405, pp. 21-26, (2000)
[3]  
Hara A.K., Leighton J.A., Sharma V.K., Heigh R.I., Fleischer D.E., Imaging of small bowel disease: Comparison of capsule endoscopy, standard endoscopy, barium examination, and CT, Radiographics, 25, pp. 697-711, (2005)
[4]  
Hara A.K., Leighton J.A., Sharma V.K., Heigh R.I., Fleischer D.E., Small bowel: Preliminary comparison of capsule endoscopy with barium study and CT, Radiology, 230, pp. 260-265, (2004)
[5]  
Goh S.T., Zekavat S.A.R., Pahlavan K., DOA-based endoscopy capsule localization and orientation estimation via unscented Kalman filter, IEEE Sensors J., 14, 11, pp. 3819-3829, (2014)
[6]  
Hu C., Meng M.Q.-H., Mandal M., Efficient magnetic localization and orientation technique for capsule endoscopy, Int. J. Inf. Acquisition, 2, pp. 23-36, (2005)
[7]  
Pourhomayoun M., Fowler M., Jin Z., A novel method for medical implant in-body localization, Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., pp. 5757-5760, (2012)
[8]  
Iakovidis D.K., Maroulis D.E., Karkanis S.A., An intelligent system for automatic detection of gastrointestinal adenomas in video endoscopy, Comput. Biol. Med., 36, 10, pp. 1084-1103, (2006)
[9]  
Sendoh M., Ishiyama K., Arai K.-I., Fabrication of magnetic acurator for use in a capsule endoscope, IEEE Trans. Magn., 39, 5, pp. 3232-3234, (2003)
[10]  
Ciuti G., Et al., Frontiers of robotic endoscopic capsules: A review, J. Micro-Bio Robot., 11, pp. 1-18, (2016)