Longitudinal monitoring of reconstructed activity concentration on a clinical time-of-flight PET/CT scanner

被引:1
|
作者
MacDonald L.R. [1 ]
Perkins A.E. [2 ]
Tung C.-H. [2 ]
机构
[1] University of Washington, Radiology Department, 1715 Northeast Columbia Road, Box 357987, Seattle, 98195-7987, WA
[2] Philips Healthcare, 595 Miner Road, Highland Heights, 44143, OH
基金
美国国家卫生研究院;
关键词
PET/CT; quality control procedure; quantitative imaging biomarker; quantitative imaging biomarker alliance; SUV variance;
D O I
10.1117/1.JMI.4.1.011004
中图分类号
学科分类号
摘要
Positron emission tomography (PET) images are potential quantitative biomarkers. Understanding long-term (months/years) biomarker variability is important for establishing confidence intervals on studies using such biomarkers over these time frames. PET biomarkers are derived from activity concentration (ρ) extracted from PET images. Over 30 months, we measured the stability of decay-normalized counts (Nn) and ρ by scanning the same 4.5-cm-diameter Ge-68 cylinder weekly, the same Na-22 point source daily, and a refilled 20-cm F-18 cylinder phantom monthly on a clinical TOF-PET/CT scanner. Longitudinal and adjacent-measurement variability was characterized. We found no drift in ρ or Nn for properly calibrated images over 24 months. During this time, ρmean ranged ±5% to 6% for count-matched Ge-68 and F-18 images, with coefficient of variation (COV) across time of 2.3% (Ge-68, 81 scans) and 3.2% (F-18, 24 scans). At typical patient image count levels the Ge-68 ρmean (ρmax) COV across time was 6.9% (9.6%). Changes in ρmean between adjacent F-18 scans (Δdays=34) ranged between ±10%, with corresponding date-matched changes in Ge-68 ρmean ranging ±2%. We recommend (1) tracking trends in Nn with image ρ as a check of quantitative data corrections/calibrations and (2) tracking both mean and COV of ρ (single time point measures) to hundredths precision using standardized uptake values. © 2016 Society of Photo-Optical Instrumentation Engineers (SPIE).
引用
收藏
相关论文
共 50 条
  • [41] Investigating Low-Dose Image Quality in Whole-Body Pediatric 18F-FDG Scans Using Time-of-Flight PET/MRI
    Schmall, Jeffrey P.
    Surti, Suleman
    Otero, Hansel J.
    Servaes, Sabah
    Karp, Joel S.
    States, Lisa J.
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (01) : 123 - 130
  • [42] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT-Initial Results
    Zeimpekis, Konstantinos G.
    Barbosa, Felipe
    Huellner, Martin
    ter Voert, Edwin
    Davison, Helen
    Veit-Haibach, Patrick
    Delso, Gaspar
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (05) : 735 - 744
  • [43] Quantitative Parametric Perfusion Images Using 15O-Labeled Water and a Clinical PET/CT Scanner: Test-Retest Variability in Lung Cancer
    van der Veldt, Astrid A. M.
    Hendrikse, N. Harry
    Harms, Hendrik J.
    Comans, Emile F. I.
    Postmus, Pieter E.
    Smit, Egbert F.
    Lammertsma, Adriaan A.
    Lubberink, Mark
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (11) : 1684 - 1690
  • [44] Clinical application of real-time PET/CT guided targeted retroperitoneal masses biopsy in diagnosing malignant tumors
    Li, Xiaomin
    Zhang, Wanchun
    BMC CANCER, 2023, 23 (01)
  • [45] Clinical Utility of Dual-Time 68Ga-Pentixafor PET/CT in Diagnosing and Subtyping Primary Aldosteronism
    Zuo, Rui
    Liu, Shuang
    Ren, Xinyi
    Li, Wenbo
    Xia, Zhu
    Xu, Lu
    Pang, Hua
    CLINICAL ENDOCRINOLOGY, 2025, : 499 - 509
  • [46] Clinical application of real-time PET/CT guided targeted retroperitoneal masses biopsy in diagnosing malignant tumors
    Xiaomin Li
    Wanchun Zhang
    BMC Cancer, 23
  • [47] Clinical count rate performance of an LSO PET/CT scanner utilizing a new front-end electronics architecture with sub-nanosecond intrinsic timing resolution
    Carney, J. P. J.
    Townsend, D. W.
    RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (12) : 2182 - 2185
  • [48] The value of Bayesian penalized likelihood reconstruction for improving lesion conspicuity of malignant lung tumors on 18F-FDG PET/CT: comparison with ordered subset expectation maximization reconstruction incorporating time-of-flight model and point spread function correction
    Yoshie Kurita
    Yasutaka Ichikawa
    Toshihiro Nakanishi
    Yoya Tomita
    Daisuke Hasegawa
    Shuichi Murashima
    Tadanori Hirano
    Hajime Sakuma
    Annals of Nuclear Medicine, 2020, 34 : 272 - 279
  • [49] 18F-FDG PET/CT for monitoring induction chemotherapy in patients with primary inoperable penile carcinoma: first clinical results
    Graafland, Niels M.
    Olmos, Renato A. Valdes
    Teertstra, Hendrik J.
    Kerst, J. Martijn
    Bergman, Andries M.
    Horenblas, Simon
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (08) : 1474 - 1480
  • [50] 18F-FDG PET/CT for monitoring induction chemotherapy in patients with primary inoperable penile carcinoma: first clinical results
    Niels M. Graafland
    Renato A. Valdés Olmos
    Hendrik J. Teertstra
    J. Martijn Kerst
    Andries M. Bergman
    Simon Horenblas
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1474 - 1480