A portable ankle-foot rehabilitation orthosis powered by electric motor

被引:0
作者
Bai, Yang [1 ]
Gao, Xueshan [1 ]
Zhao, Jun [2 ]
Jin, Fei [3 ]
Dai, Fuquan [1 ]
Lv, Yunqi [1 ]
机构
[1] School of Mechatronical Engineering, Beijing Institute of Technology, Beijing
[2] Department of Neurological Rehabilitation, China Rehabilitation Research Center, Beijing
[3] Rehabilitation Engineering Research Institute, China Rehabilitation Research Center, Beijing
来源
Open Mechanical Engineering Journal | 2015年 / 9卷 / 01期
关键词
Ankle rehabilitation; Ankle-foot; Dorsiflexion; Plantar flexion; Powered orthosis;
D O I
10.2174/1874155X01509010982
中图分类号
学科分类号
摘要
Powered ankle-foot orthosis can not only prevent foot-drop and assist patients’ walking but also improve the ankle joint movement for patients with dysfunction caused by the various injuries and nervous system diseases. Common ankle rehabilitation devices limit the ankle injury patients’ rehabilitation training within fixed places, so a portable powered ankle-foot orthosis is presented in this paper to enable the patients to continue their work normally with the treatment. The orthosis employs electric motor drive mode to provide ankle dorsiflexion and plantar flexion assistance during patient’s walking. First, the ankle-foot dynamics model is established and the gait is analyzed for the powered ankle-foot orthosis system. Then, a new mechanical structure including wearing parts, analogous ankle joint and transmission is described. For the small installation space between the instep and the knee, the compact transmission mechanism is paid more attention and the finite element method is adopted to optimize the key structure after the force analysis. In addition, the closed-loop control system is chosen for the orthosis position and speed control. At last, wearing and movement experiments on the prototype are carried out, which validates the stability and rationality of the structure design and the effectiveness of the motion control. It has great significance in promoting patient's rehabilitation to help them return to the society. © Cao et al.;.
引用
收藏
页码:982 / 991
页数:9
相关论文
共 25 条
[1]  
Zhang M., Davies T.C., Xie S., Effectiveness of robot-assisted therapy on ankle rehabilitation-a systematic review, J Neuroeng. Rehabil., 10, (2013)
[2]  
Middleton E.A., Hurley G.R.B., McIlwain J.S., The role of rigid and hinged polypropylene ankle-foot-orthoses in the management of cerebral palsy: A case study, Prosthet. Orthot. Int., 12, 3, pp. 129-135, (1988)
[3]  
Herr H., Kornbluh R., New horizons for orthotic and prosthetic technology: Artificial muscle for ambulation, Proc. SPIE 5385, Smart Structures and Materials 2004: Electroactive Polymer Actuators and Devices, pp. 1-9, (2004)
[4]  
Furusho J., Kikuchi T., Tokuda M., Kakehashi T., Ikeda K., Morimoto S., Hashimoto Y., Tomiyama H., Nakagawa A., Akazawa Y., Development of shear type compact MR brake for the intelligent ankle-foot orthosis and its control, Proc. 2007 IEEE Int. Conf. on Rehabilitation Robotics, Noordwijk, Netherlands, pp. 89-94, (2007)
[5]  
Winter D.A., Sienko S.E., Biomechanics of below-knee amputee gait, J. Biomech, 21, pp. 361-367, (1988)
[6]  
Eng J.J., Winter D.A., Kinetic analysis of the lower limbs during walking: What information can be gained from a threedimensional model, J. Biomech., 28, 6, pp. 753-758, (1995)
[7]  
Brackx B., Van Damme M., Matthys A., Vanderborght B., Lefeber D., Passive ankle-Foot prosthesis prototype with extended push-off, Int. J. Adv. Robot. Syst., 10, (2013)
[8]  
Sanz-Merodio D., Cestari M., Arevalo J.C., Garcia E., Control motion approach of a lower limb orthosis to reduce energy consumption, Int. J. Adv. Robot. Syst., 9, (2012)
[9]  
Chin R., Hsiao-Wecksler E.T., Loth E., Kogler G., Manwaring S.D., Tyson S.N., Shorter K.A., Gilmer J.N., A pneumatic power harvesting ankle-foot orthosis to prevent footdrop, J. Neuroeng. Rehabil., 6, (2009)
[10]  
Shorter K.A., Kogler G.F., Loth E., Durfee W.K., Hsiao-Wecksler E.T., A portable powered ankle-foot orthosis for rehabilitation, J. Rehabil. Res. Dev., 48, 4, pp. 459-472, (2011)