Development of dimensional X-ray computed tomography

被引:0
作者
National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba [1 ]
Ibaraki
305-8563, Japan
机构
[1] National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, 305-8563, Ibaraki
来源
Int. J. Autom. Technol. | / 5卷 / 567-571期
关键词
Dimensional measurement; Industrial standards; Reference gauge; X-ray computed tomography;
D O I
10.20965/ijat.2015.p0567
中图分类号
学科分类号
摘要
Recently, a strong need has arisen for a dimensional X-ray computed tomography system that is capable of dimensionalmeasurements. This is because the speedy realization of dimensional measurements for outward forms and inward forms on dense spatial points remarkably simplifies and accelerates production loop. However, although the image obtained via XCT describes the structure clearly and in great detail, dimensional metrology by means of XCT is not simple. The National Metrology Institute of Japan has been carrying out performance tests using gauges that include the gauges proposed in ISO10360. In this work, the magnification variation correction is carefully presented, and a maximum deviation of less than 5 μm is shown to be possible by means of the measurement of the forest phantom of 27 ruby spheres, the locations of which are calibrated by the coordinate measuring machine. © 2015, Fuji Technology Press. All rights reserved.
引用
收藏
页码:567 / 571
页数:4
相关论文
共 50 条
  • [1] Performance testing of dimensional X-ray computed tomography systems
    Zwanenburg, E. A.
    Williams, M. A.
    Warnett, J. M.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2022, 77 : 179 - 193
  • [2] On the uncertainty of surface determination in x-ray computed tomography for dimensional metrology
    Lifton, J. J.
    Malcolm, A. A.
    McBride, J. W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (03)
  • [3] Effect of the number of projections on dimensional measurements with X-ray computed tomography
    Villarraga-Gomez, Herminso
    Smith, Stuart T.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2020, 66 : 445 - 456
  • [4] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [5] Image Analysis in X-ray Computed Tomography
    Seletchi, Emilia Dana
    Sutac, Victor
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON VIRTUAL LEARNING: VIRTUAL LEARNING - VIRTUAL REALITY: MODELS & METHODOLOGIES, TECHNOLOGIES, SOFTWARE SOLUTIONS, 2006, : 187 - +
  • [6] X-ray computed tomography in life sciences
    Shelley D. Rawson
    Jekaterina Maksimcuka
    Philip J. Withers
    Sarah H. Cartmell
    BMC Biology, 18
  • [7] Charting the course towards dimensional measurement traceability by x-ray computed tomography
    Ferrucci, Massimiliano
    Ametova, Evelina
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (09)
  • [8] X-ray computed tomography of frozen soil
    Torrance, J. K.
    Elliot, T.
    Martin, R.
    Heck, R. J.
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2008, 53 (01) : 75 - 82
  • [9] X-ray computed tomography in life sciences
    Rawson, Shelley D.
    Maksimcuka, Jekaterina
    Withers, Philip J.
    Cartmell, Sarah H.
    BMC BIOLOGY, 2020, 18 (01)
  • [10] Measurement uncertainty evaluation in dimensional X-ray computed tomography using the bootstrap method
    Jochen Hiller
    Gianfranco Genta
    Giulio Barbato
    Leonardo De Chiffre
    Raffaello Levi
    International Journal of Precision Engineering and Manufacturing, 2014, 15 : 617 - 622