Braced Frame Symmetrical and Asymmetrical Friction Connection Performance

被引:7
|
作者
Xie R. [1 ]
Golondrino J.C. [2 ]
Macrae G. [1 ]
Clifton C. [3 ]
机构
[1] Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch
[2] Department of Civil Engineering, National University of Colombia, Manizales
[3] Department of Civil and Environmental Engineering, University of Auckland, Auckland
关键词
Energy Dissipation; Friction Connections; High Tensile Bolts; Low Damage Structures; Wear Resisting Shims;
D O I
10.4028/www.scientific.net/KEM.763.216
中图分类号
学科分类号
摘要
This paper describes quasi-static testing of Asymmetrical Friction Connection (AFC) and Symmetrical Friction Connections (SFC) in steel braces. It is shown that stable energy dissipation mechanisms have been achieved in braces using Bisalloy 500 shims on the sliding surface. When incorporated into a moment frame, the braces and the moment resisting frames underwent large displacements without significant frame yielding. The effective coefficient of friction is shown to be dependent on prying. © 2018 Trans Tech Publications Ltd, Switzerland.
引用
收藏
页码:216 / 223
页数:7
相关论文
共 50 条
  • [1] Buckling-restrained braced frame connection performance
    Wigle, Victoria R.
    Fahnestock, Larry A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (01) : 65 - 74
  • [2] Evaluation of performance of eccentric braced frame with friction damper
    Amiri, J. Vaseghi
    Navayinia, B.
    Navaei, S.
    STRUCTURAL ENGINEERING AND MECHANICS, 2011, 39 (05) : 717 - 732
  • [3] Investigation of RBS Connection Ductility in Eccentrically Braced Frame
    Naghipour, M.
    Javadi, N.
    Naghipour, A.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [4] A parametric assessment of friction damper in eccentric braced frame
    Department of Civil Engineering, Iran
    不详
    不详
    World Acad. Sci. Eng. Technol., 2009, (208-212):
  • [5] Performance study of frictional prefabricated connection nodes in self-centering braced steel frame
    Xu, Long-He
    Huang, Chu-Cheng
    Xie, Xing-Si
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (07): : 1239 - 1249
  • [6] Evaluation of behavior and performance of the braced/unbraced four story of steel frame with semi rigid connection
    Teruna, Daniel Rumbi
    2ND CONFERENCE FOR CIVIL ENGINEERING RESEARCH NETWORKS (CONCERN-2 2018), 2019, 270
  • [7] Splice Connection Details for Eccentrically Braced Frame Replaceable Links
    Bozkurt, Mehmet Bakır
    Topkaya, Cem
    ce/papers, 2019, 3 (3-4) : 463 - 468
  • [8] An asymmetrical damper to improve tension-only braced frame performance under mainshock and aftershocks coupling strikes
    Gu Z.
    Fan Y.
    Yuan M.
    Lu W.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (04): : 1 - 9
  • [9] Study of the Rigidity of a Concentrically Braced Frame Connection Using End Plates
    Parent, Serge
    Roy, Nathalie
    Gauthier, David
    ce/papers, 2019, 3 (3-4) : 367 - 372
  • [10] Parametric study on seismic response of the knee braced frame with friction damper
    Ghafouri-Nejad, Amir
    Alirezaei, Mehdi
    Mirhosseini, S. Mohammad
    Zeighami, Ehsanollah
    STRUCTURES, 2021, 32 : 2073 - 2087