Comparison of Pulse Sequences of Magnetic Resonance Imaging for Optimization of Timing and Image Quality

被引:0
作者
Amin N. [1 ]
Yousaf M. [2 ]
Javid M.A. [3 ]
Farooq A. [1 ]
机构
[1] Department of Physics, COMSATS University Islamabad, Lahore Campus
[2] Mathematics Department, COMSATS University Islamabad, Lahore Campus
[3] Department of Basic Sciences, UET, Taxila
关键词
Diagnosis; Imaging; Magnetic Resonance; Phantoms; Signal to noise ratio;
D O I
10.22038/ijmp.2019.38606.1501
中图分类号
学科分类号
摘要
Introduction: The present study aimed to three frequently used pulse sequences of magnetic resonance imaging (MRI) to assess the image quality of theses pulse sequences at short acquisition time. Material and Methods: For the purpose of study two tissue equivalent gels were prepared. One gel was made from Polysaccharide and Agarose, whereas second gel was obtained from Ferrous Benzoic Xylenol Orange (FBX) which is tissue equivalent material. 6MV photons were used to irradiate FBX gel from linear accelerator with 25 Gray dose. Imaging parameters are performed in repetition time (TR) for experimental variations. The quantitative analysis included contrast-to-noise ratio (CNR) and signal to noise ratio (SNR). Results: As evidenced by obtained results at 1.5 Tesla, Fast Spin Echo (FSE) and Fast Fluid Attenuated Inversion Recovery (FLAIR) were most comparable in SNR although, acquisition time of FSE is 62%, 9 %, and 15% less than FLAIR at different values of 4000ms, 4200ms and 4600ms of TR. CNR of Conventional Spin Echo (CSE) was 143% and 93% better than FSE and FLAIR respectively. The time difference between CSE and FSE was 6 min and 34 sec while this difference was 6 min and 43 sec between CSE and FLAIR. Conclusion: FSE and FLAIR produced optimal image quality for many tissues. Their reduced acquisition time could make them perfect option for patients who cannot tolerate longer imaging time. Nonetheless long acquisition time cannot undervalue importance of CSE since it has yielded significantly higher contrast and SNR in T2-weighted images among other pulse sequences of MRI. © 2020. All Rights Reserved.
引用
收藏
页码:350 / 358
页数:8
相关论文
共 50 条
[31]   Comparison of complications rates between multiparametric magnetic resonance imaging-transrectal ultrasound (TRUS) fusion and systematic TRUS prostatic biopsies [J].
Queiroz, Marcos R. G. ;
Falsarella, Priscila M. ;
Mariotti, Guilherme Cayres ;
Lemos, Gustavo C. ;
Baroni, Ronaldo H. ;
Mussi, Thais Caldara ;
Garcia, Rodrigo G. .
ABDOMINAL RADIOLOGY, 2019, 44 (02) :732-738
[32]   Comparison of different types of cardiac amyloidosis by cardiac magnetic resonance imaging [J].
Kristen, Arnt V. ;
Siepen, Fabian Aus Dem ;
Scherer, Katrin ;
Kammerer, Rebekka ;
Andre, Florian ;
Buss, Sebastian J. ;
Bauer, Ralf ;
Lehrke, Stephanie ;
Voss, Andreas ;
Giannitsis, Evangelos ;
Katus, Hugo A. ;
Steen, Henning .
AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2015, 22 (02) :132-141
[33]   Computing Optimization Technique in Enhancing Magnetic Resonance Imaging and Brain Segmentation of Hypophysis Cerebri Based on Morphological Based Image Processing [J].
Zhang, Xiyu ;
Liu, Xinqi ;
Lin, Weiwei .
JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (04) :1063-1070
[34]   Comparison of Intrauterine and Postnatal Brain Magnetic Resonance Imaging: Systematic Review [J].
Arechvo, Anastasija ;
Nicolaides, Kypros H. ;
Whitby, Elspeth H. ;
Hart, Anthony R. .
PEDIATRIC NEUROLOGY, 2025, 166 :47-54
[35]   Comparison of magnetic resonance imaging findings in temporomandibular joints of the two sides [J].
Daniele Manfredini ;
Stefano Bonnini ;
Edoardo Stellini ;
Luigi Salmaso ;
Luca Guarda-Nardini .
Clinical Oral Investigations, 2014, 18 :499-506
[36]   Comparison of magnetic resonance imaging findings in temporomandibular joints of the two sides [J].
Manfredini, Daniele ;
Bonnini, Stefano ;
Stellini, Edoardo ;
Salmaso, Luigi ;
Guarda-Nardini, Luca .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) :499-506
[37]   Common fetal measurements: A comparison between ultrasound and magnetic resonance imaging [J].
Parkar, Anagha P. ;
Olsen, Oystein E. ;
Gjelland, Knut ;
Kiserud, Torvid ;
Rosendahl, Karen .
ACTA RADIOLOGICA, 2010, 51 (01) :85-91
[38]   COMPARISON OF TWO FAT-SUPPRESSED MAGNETIC RESONANCE IMAGING PULSE SEQUENCES TO STANDARD T2-WEIGHTED IMAGES FOR BRAIN PARENCHYMAL CONTRAST AND LESION DETECTION IN DOGS WITH INFLAMMATORY INTRACRANIAL DISEASE [J].
Young, Benjamin D. ;
Mankin, Joseph M. ;
Griffin, John F. ;
Fosgate, Geoffrey T. ;
Fowler, Jennifer L. ;
Levine, Jonathan M. .
VETERINARY RADIOLOGY & ULTRASOUND, 2015, 56 (02) :204-211
[39]   Efficient Cascade Model for Pathological Brain Image Detection by Magnetic Resonance Imaging [J].
Jha, Debesh ;
Kim, Ji-In ;
Lee, Bumshik ;
Kwon, Goo-Rak .
JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (08) :1744-1752
[40]   Evaluation of cartilage coverage with magnetic resonance imaging in residual dysplasia and its impact on surgical timing [J].
Dogan, Ozgur ;
Caliskan, Emrah ;
Duran, Semra ;
Bicimoglu, Ali .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2019, 53 (05) :351-355