Comparison of Pulse Sequences of Magnetic Resonance Imaging for Optimization of Timing and Image Quality

被引:0
作者
Amin N. [1 ]
Yousaf M. [2 ]
Javid M.A. [3 ]
Farooq A. [1 ]
机构
[1] Department of Physics, COMSATS University Islamabad, Lahore Campus
[2] Mathematics Department, COMSATS University Islamabad, Lahore Campus
[3] Department of Basic Sciences, UET, Taxila
关键词
Diagnosis; Imaging; Magnetic Resonance; Phantoms; Signal to noise ratio;
D O I
10.22038/ijmp.2019.38606.1501
中图分类号
学科分类号
摘要
Introduction: The present study aimed to three frequently used pulse sequences of magnetic resonance imaging (MRI) to assess the image quality of theses pulse sequences at short acquisition time. Material and Methods: For the purpose of study two tissue equivalent gels were prepared. One gel was made from Polysaccharide and Agarose, whereas second gel was obtained from Ferrous Benzoic Xylenol Orange (FBX) which is tissue equivalent material. 6MV photons were used to irradiate FBX gel from linear accelerator with 25 Gray dose. Imaging parameters are performed in repetition time (TR) for experimental variations. The quantitative analysis included contrast-to-noise ratio (CNR) and signal to noise ratio (SNR). Results: As evidenced by obtained results at 1.5 Tesla, Fast Spin Echo (FSE) and Fast Fluid Attenuated Inversion Recovery (FLAIR) were most comparable in SNR although, acquisition time of FSE is 62%, 9 %, and 15% less than FLAIR at different values of 4000ms, 4200ms and 4600ms of TR. CNR of Conventional Spin Echo (CSE) was 143% and 93% better than FSE and FLAIR respectively. The time difference between CSE and FSE was 6 min and 34 sec while this difference was 6 min and 43 sec between CSE and FLAIR. Conclusion: FSE and FLAIR produced optimal image quality for many tissues. Their reduced acquisition time could make them perfect option for patients who cannot tolerate longer imaging time. Nonetheless long acquisition time cannot undervalue importance of CSE since it has yielded significantly higher contrast and SNR in T2-weighted images among other pulse sequences of MRI. © 2020. All Rights Reserved.
引用
收藏
页码:350 / 358
页数:8
相关论文
共 50 条
[21]   MAGNETIC-RESONANCE-IMAGING IN HUMAN LYMPHEDEMA - COMPARISON WITH LYMPHANGIOSCINTIGRAPHY [J].
CASE, TC ;
WITTE, CL ;
WITTE, MH ;
UNGER, EC ;
WILLIAMS, WH .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :549-558
[22]   Comparison of the Timing of Hepatic Arterial Phase and Image Quality Using Test-Bolus and Bolus-Tracking Techniques in Gadolinium-Ethoxybenzyl-Diethylenetriamine Pentaacetic Acid-Enhanced Hepatic Dynamic Magnetic Resonance Imaging [J].
Iyama, Yuji ;
Nakaura, Takeshi ;
Yokoyama, Koichi ;
Kidoh, Masafumi ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Namimoto, Tomohiro ;
Yamashita, Yasuyuki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) :638-643
[23]   Comparison of image quality and in vivo appearance of the normal equine nasal cavities and paranasal sinuses in computed tomography and high field (3.0 T) magnetic resonance imaging [J].
Kaminsky, Joachim ;
Bienert-Zeit, Astrid ;
Hellige, Maren ;
Rohn, Karl ;
Ohnesorge, Bernhard .
BMC VETERINARY RESEARCH, 2016, 12
[24]   Comparison of Clinical Characteristics and Magnetic Resonance Imaging of Salivary Glands With Magnetic Resonance Sialography in Sjogren's Syndrome [J].
Andre, Raphael ;
Becker, Minerva ;
Lombardi, Tommaso ;
Buchholzer, Samanta ;
Marchal, Francis ;
Seebach, Jorg D. .
LARYNGOSCOPE, 2021, 131 (01) :E83-E89
[25]   Perinatal and paediatric post-mortem magnetic resonance imaging (PMMR): sequences and technique [J].
Norman, Wendy ;
Jawad, Noorulhuda ;
Jones, Rod ;
Taylor, Andrew M. ;
Arthurs, Owen J. .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062)
[26]   The Osteoarthritis Initiative (OAI) magnetic resonance imaging quality assurance update [J].
Schneider, E. ;
NessAiver, M. .
OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) :110-116
[27]   Quality Control of the Clinical Parameters for Justifying Requests for Magnetic Resonance Imaging [J].
del Campo, Lourdes ;
Ocon, Elena ;
Gomez-Leon, Nieves .
RADIOLOGIA, 2005, 47 (03) :139-143
[28]   Contribution for the funcionality and the safety in magnetic resonance: an approach for the imaging quality. [J].
Moraes, L ;
Garcia, R .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :3613-3616
[29]   Quantification of blood flow in the carotid arteries -: Comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences [J].
Seitz, J ;
Strotzer, M ;
Wild, T ;
Nitz, WR ;
Völk, M ;
Lenhart, M ;
Feuerbach, S .
INVESTIGATIVE RADIOLOGY, 2001, 36 (11) :642-647
[30]   AN EASY-TO-USE IMAGE LABELING PLATFORM FOR AUTOMATIC MAGNETIC RESONANCE IMAGE QUALITY ASSESSMENT [J].
Kuestner, Thomas ;
Wolf, Philip ;
Schwartz, Martin ;
Liebgott, Annika ;
Schick, Fritz ;
Gatidis, Sergios ;
Yang, Bin .
2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, :754-757