Applicability research of RELAP5 for steam generator tube rupture accident of AP1000 NPP

被引:0
|
作者
Fang J. [1 ]
Wu N. [1 ]
Qi T. [1 ]
机构
[1] China Nuclear Power Engineering Co., Ltd., Beijing
来源
关键词
Accident analysis; LOFTTR2; RELAP5; SGTR; Tube rupture;
D O I
10.13832/j.jnpe.2016.03.0070
中图分类号
学科分类号
摘要
Steam generator tube rupture (SGTR) accident is a significant design basis accident which shall be analyzed in PWR nuclear power plant safety analysis reports. Thermo-hydraulic analysis of SGTR accident for licensing has been done using a specific code entitled LOFTTR2.To validate the applicability of RELAP5 for AP1000 SGTR accident, a RELAP5 model for AP1000 is established and used to assess this accident. Results show that both the accident progression and the doses result of RELAP5 calculation correspond well with that in Safety Analysis Report. Thus, RELAP5 and RELAP5 model of AP1000 can apply to other SGTR type analysis. © 2016, Editorial Board of Journal of Nuclear Power Engineering. All right reserved.
引用
收藏
页码:70 / 74
页数:4
相关论文
empty
未找到相关数据