Development of 72/84 kV dry air insulated dead tank type VCB

被引:0
|
作者
Japan AE Power Systems Corporation, 585, Shimonakamizo, Higashimakado, Numazu 410-0865, Japan [1 ]
机构
来源
IEEJ Trans. Power Energy | / 2卷 / 353-360+13期
关键词
Air insulation - Arc observation - Axial magnetic field electrode - Short circuit tests - Vacuum circuit breaker;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:353 / 360
相关论文
共 29 条
  • [1] Development of 72/84-kV Dry Air-Insulated Dead Tank VCB
    Saito, Hitoshi
    Nagatake, Kazuhiro
    Komatsu, Hideki
    Takeshita, Yukihiro
    Matsui, Yoshihiko
    Katsumata, Kiyohito
    Sakaki, Masayuki
    ELECTRICAL ENGINEERING IN JAPAN, 2011, 177 (01) : 1 - 10
  • [2] Development of 72/84 kV dead-tank VCB with rated normal current of 3000 A
    Saito, Hitoshi
    Nagatake, Kazuhiro
    Yamauchi, Kazuki
    Takeshita, Yukihiro
    Kobayashi, Tooru
    Cho, Terumichi
    Katsumata, Kiyohito
    Sakaki, Masayuki
    2013 2ND INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2013,
  • [4] Interruption Behaviours with 84/72-kV VCB and GCB
    Tokoyoda, Sho
    Takeda, Toshinobu
    Kamei, Kenji
    Yoshida, Daisuke
    Ito, Hiraki
    2013 2ND INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2013,
  • [5] 72/84kV Cubicle-Type Gas-Insulated Switchgear
    Sato, T.
    Numata, S.
    Tanaka, H.
    Nishizaki, M.
    Mitsubishi Denki Giho, 70 (06):
  • [6] Insulation Technology in Dry Air and Vacuum for a 72-kV Low-Pressure Dry-Air Insulated Switchgear
    Yoshida, Tadahiro
    Koga, Hiromi
    Harada, Takakazu
    Miki, Shinichi
    Arioka, Masahiro
    Sato, Shinji
    Yoshida, Satoru
    Inoue, Naoaki
    Maruyama, Akihiko
    Takeuchi, Toshie
    ELECTRICAL ENGINEERING IN JAPAN, 2011, 175 (01) : 18 - 24
  • [7] Development of a high pressure air-insulated 72/84 kV disconnecting switch corresponding to bus-transfer current switching
    Power and Industrial Systems R and D Laboratory, Hitachi, Ltd., 7-2-1, Omika-cho, Hitachi 319-1221
    不详
    不详
    不详
    不详
    不详
    IEEJ Trans. Power Energy, 2006, 9 (947-953):
  • [8] Application Condition of 40.5kV Air Insulated Metal Enclosed Switchgear with VCB in China
    Li, Hongmei
    Tan, Dongxian
    Liu, Yuhua
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [9] Development of a High-Pressure Air-Insulated 72/84-kV Disconnecting Switch Corresponding to Bus-Transfer Current Switching
    Rokunohe, Toshiaki
    Yagihashi, Yoshitaka
    Endo, Fumihiro
    Oomori, Takashi
    ELECTRICAL ENGINEERING IN JAPAN, 2009, 167 (02) : 48 - 55
  • [10] Development of 72-kV high-pressure air-insulated GIS with vacuum circuit breaker
    Rokunohe, Toshiaki
    Yagihashi, Yoshitaka
    Endo, Fumihiro
    Aoyagi, Kenji
    Saitoh, Hitoshi
    Oomori, Takashi
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 2006, 157 (04): : 13 - 23