Voltage sag due to pollution induced flashover across ceramic insulator strings

被引:0
|
作者
Subba Reddy B. [1 ]
Goswami A.K. [2 ]
机构
[1] Electrical Engg, Indian Institute of Science, Bangalore
[2] Electrical Engg, NIT Silchar, Silchar, Assam
关键词
Ceramic disc insulators; flashovers; leakage current; pollution/contamination; power transmission; voltage sag;
D O I
10.1515/ijeeps-2016-0160
中图分类号
学科分类号
摘要
Voltage sag or voltage dips are significant to industrial reliability. There is a necessity to characterize the feeder level power quality (PQ) and the PQ performance among various utility companies. Contamination/pollution induced flashover is the ultimate consequence of the creeping discharges across the insulator strings which induce voltage sag. These have a severe threat on the safe and reliable operation of power systems. In the present work an attempt has been made to experimentally investigate the occurrence of voltage sag/dips during pollution induced flashovers. Results show significant dip/sag in the voltage magnitude during the flashover process. © 2017 Walter de Gruyter GmbH, Berlin/Boston.
引用
收藏
相关论文
共 38 条
  • [1] Study of the Influence of Test Methods on DC Pollution Flashover Voltage of Insulator Strings and its Flashover Process
    Zhang, Zhijin
    Jiang, Xinliang
    Sun, Caixin
    Hu, Jianlin
    Huang, Haizhou
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (06) : 1787 - 1795
  • [2] DC pollution flashover model and its validation of polluted insulator strings
    Zhang, Zhijin
    Jiang, Xingliang
    Sun, Caixin
    Hu, Jianlin
    Yuan, Jihe
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (04): : 36 - 41
  • [3] Resistance Measurements and Interpretations Relating to Flashover of Artificially Contaminated Ceramic Insulator Strings
    B.Subba Reddy
    G.R.Nagabhushana
    Plasma Science & Technology, 2003, (06) : 2093 - 2100
  • [4] Resistance measurements and interpretations relating to flashover of artificially contaminated ceramic insulator strings
    Reddy, BS
    Nagabhushana, GR
    PLASMA SCIENCE & TECHNOLOGY, 2003, 5 (06) : 2093 - 2100
  • [5] Effect of inverted T arrangement on AC pollution flashover characteristics of insulator strings
    Jiang, Xingliang
    Ren, Xiaodong
    Wang, Han
    Han, Xingbo
    Bi, Conglai
    Li, Zhiyu
    Hou, Ledong
    HIGH VOLTAGE, 2019, 4 (02) : 97 - 104
  • [6] Pollution Flashover Characteristics of Insulator Strings with Inverted T-type Arrangement
    Jiang X.
    Wang H.
    Yang Z.
    Han X.
    Wu H.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (03): : 701 - 707
  • [7] Research on the Influence of surface accumulation charge on flashover voltage of ceramic insulator
    Geng Jiang-hai
    Jia Bo-yan
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 244 - 246
  • [8] AC pollution flashover performance of insulator strings partially treated with semiconductive RTV coating
    Jia, Zhidong
    Hu, Yarong
    Guan, Zhicheng
    Wei, Xiaoxing
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2633 - 2639
  • [9] Influence of Different Layout Methods on Artificial Pollution Flashover Characteristics of AC Insulator Strings
    Jiang X.
    Ren X.
    Han X.
    Hou L.
    Huang Y.
    Ren, Xiaodong (xdrcqu@163.com), 1600, China Machine Press (35): : 896 - 905
  • [10] AUTOMATIC INSULATOR-WASHING SYSTEM TO PREVENT FLASHOVER DUE TO POLLUTION
    CAKEBREAD, RJ
    BROWN, HJ
    DAWKINS, RB
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1978, 125 (12): : 1363 - 1366