Influence of AC transmission lines on parallelly erected ±500 kV HVDC double circuit transmission lines and suppression measure

被引:0
|
作者
Li, Tao [1 ]
Li, Xin-Nian [1 ]
Jiang, Wei-Ping [1 ]
Gao, Jian [2 ]
机构
[1] China Electric Power Research Institute, Beijing 100192, China
[2] Tianjin Electric Power Engineering Supervision Co. Ltd, Tianjin 300143, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:70 / 75
相关论文
共 50 条
  • [41] Experimental research on live working carried on double circuit vertically arranged 500 kV compact transmission lines on the same tower
    Ding, Yujian
    Song, Gang
    Chen, Jiamiao
    Ying, Jianguo
    Xing, Yuelong
    Li, Qingfeng
    Liao, Weiming
    Dianwang Jishu/Power System Technology, 2013, 37 (11): : 3281 - 3287
  • [42] Research on Safety Protection for Live Working on 1000kV AC Transmission Line with AC and DC Multi-circuit Transmission Lines
    Xie, Yan
    Li, Mu
    Xiang, Tao
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [43] Noise Suppression of Corona Current Measurement From HVdc Transmission Lines
    Wang, Qiusheng
    Kundur, Deepa
    Yuan, Haiwen
    Liu, Yuanqing
    Lu, Jiayu
    Ma, Zhao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (02) : 264 - 275
  • [44] Calculation of inductive voltage and current for 500 kV double circuits transmission lines on single tower
    Hu, Dan-Hui
    Tu, Cai-Qi
    Jiang, Wei
    Chai, Ya-Jing
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (09): : 1927 - 1931
  • [45] Grading Ring Optimization for Tension Porcelain Insulator String on Double Circuit Tension Tower in 1000 kV AC Transmission Lines
    Yang, Xi
    Peng, Zongren
    Lia, Jintao
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [46] Typical models of compact transmission lines and application prospect in 500KV AC system of China
    Zhang, B
    Cen, WH
    Huang, JY
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 218 - 222
  • [47] Back-flashover resistance level of ±800 kV/500 kV AC-DC hybrid transmission lines
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu
    610031, China
    不详
    610000, China
    不详
    200122, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 10 (101-106 and 114):
  • [48] Research on the electric unbalance degree of multiple transmission lines non-parallelly erected entirely in one common corridor
    Zhu, Jun
    Wu, Guangning
    Shi, Chaoqun
    Gan, Degang
    Cao, Yongxing
    Wu, Chi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 85 : 67 - 76
  • [49] Control Strategy of Grounding Electrode Current for Double-circuit HVDC Transmission Lines on the Same Tower
    Zhu Y.
    Guo Q.
    Huang L.
    Li S.
    Guan H.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2018, 42 (18): : 169 - 176
  • [50] Calculation of the total electric field at ground level for double-circuit HVDC overhead transmission lines
    Department of Electrical Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2008, 6 (32-36):