Application of imaging VISAR to pre-heating experiment of Au conical target for fast ignition

被引:0
作者
Xu, Tao [1 ]
Wei, Huiyue [1 ]
Wang, Feng [1 ]
Peng, Xiaoshi [1 ]
Shan, Lianqiang [1 ]
Liu, Shenye [1 ]
机构
[1] Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang
来源
Guangxue Xuebao/Acta Optica Sinica | 2013年 / 33卷 / 02期
关键词
Au conical target; Fast ignition; Imaging velocity interferometer system for any reflector; Measurement; Pre-heating;
D O I
10.3788/AOS201333.0212003
中图分类号
学科分类号
摘要
The application of the imaging VISAR to the pre-heating experiment of Au conical target for fast ignition is proposed. The pre-heating experiments using different kinds of Au cones which have the diverse thicknesses of 5 μm and 10 μm are studied. The experimental data show that the velocity of the two kinds of cone are 2.2 km/s and 0.6 km/s. Details of the pre-heating physical progress are described, which indicate that the Au cone having thickness of 10 μm is less affected by the pre-heating effect. The experimental results show that the imaging VISAR has the ability to measure the low velocity of free surface, and the whole facility is effective for further experiment.
引用
收藏
相关论文
共 15 条
  • [1] Tabak M., Hammer J.M., Glinsky M.E., Et al., Ignition and high gain with ultra powerful lasers, Phys. Plasmas, 1, 5, pp. 1626-1634, (1994)
  • [2] Sentoku Y., Esirkepov T.Z., Mima K., Et al., Bursts of supper reflected laser light from inhomogeneous plasmas due to the generation of relativistic solitary waves, Phys. Rev. Lett., 83, 17, (1999)
  • [3] Tanaka K.A., Kodama R., Mima K., Et al., Basic and integrated studies for fast ignition, Phys. Plasmas, 10, 5, pp. 1925-1930, (2003)
  • [4] Kodama R., Mima K., Tanaka K.A., Et al., Fast ignition research at the institute of laser engineering, osaka university, Phys. Plasmas, 8, 5, pp. 2268-2274, (2001)
  • [5] Norimatsu T., Nagai K., Takeda T., Et al., Update for the drag force on an injected pellet and target fabrication for inertial fusion, Fusion Sci. Technol., 43, 3, pp. 339-345, (2003)
  • [6] Sentoku Y., Mima K., Ruhl H., Et al., Laser light and hot electron micro focusing using a conical target, Phys. Plasmas, 11, 6, pp. 3083-3087, (2004)
  • [7] Peng X., Wang F., Liu S., Et al., Development of an imaging velocity interferometer system for any reflector, Acta Optica Sinica, 29, 11, pp. 3207-3211, (2009)
  • [8] Barker L.M., Hollenbach R.E., Laser interferometer for measuring high velocities of any reflecting surface, J. Appl. Phys., 43, 11, pp. 4669-4675, (1972)
  • [9] Hu S., Laser Interferometry Technique for Measuring Velocity, pp. 32-33, (2001)
  • [10] Cellier P.M., Bradley D.K., Collins G.W., Et al., Line-imaging velocity meter for shock diagnostic at the OMEGA laser facility, Rev. Sci. Instrum., 75, 11, pp. 4916-4929, (2004)