Experimental Study on the Influence of Heat Flux and Filling Ratio on the Operation Characteristics of Plate Evaporator Loop Heat Pipe

被引:0
|
作者
Zhang, Wei-Long [1 ]
Wei, Xin-Li [1 ,2 ]
Meng, Xian-Rui [1 ,2 ]
Yang, Ling-Xiao [1 ]
Li, Zhan [1 ,2 ]
Zhao, Ling-Hua [1 ]
Ye, Shong [1 ]
机构
[1] School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou,450001, China
[2] Research Center on the Technology and Equipments for Energy Saving in Thermal Energy System, Ministry of Education, Zhengzhou,450001, China
来源
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics | 2020年 / 41卷 / 08期
关键词
Heat resistance;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, the effects of different heat fluxes on the operating characteristics of the plate evaporator loop heat pipe system are studied experimentally. The effects of the filling ratio on the evaporator cover temperature and system thermal resistance are also studied. The results show that the plate evaporator loop heat pipe system can operate stably in the range of 0.2∼1 W/cm2 heat flux. The overall temperature of the evaporator increases with the increase of heat flux, and the thermal resistance increases with the heat flux. Under the experimental conditions, when the filling ratio is 55%, the temperature and thermal resistance of the upper cover of the system evaporator reach the lowest value. At this time, the heat transfer capacity of the system reaches the strongest, and the optimal filling ratio of the system is 55%. © 2020, Science Press. All right reserved.
引用
收藏
页码:2020 / 2024
相关论文
共 50 条
  • [1] Experimental study of an ammonia loop heat pipe with a flat plate evaporator
    Song, He
    Liu Zhi-chun
    Jing, Zhao
    Chi, Jiang
    Yang Jin-guo
    Wei, Liu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 : 1050 - 1055
  • [2] The influence of filling ratio on the performance of loop heat pipe
    Key Laboratory of Renewable Energy of Chinese Academy of Sciences, Laboratory of Advanced Energy Systems of Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou, China
    Guangdianzi Jiguang, 4 (676-681):
  • [3] Experimental study on the operating characteristics of a flat bifacial evaporator loop heat pipe
    Joung, Wukchul
    Yu, Taeu
    Lee, Jinho
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (1-3) : 276 - 285
  • [4] Experimental Study on the Secondary Evaporator of a Cryogenic Loop Heat Pipe
    Zhao, Ya-nan
    Yan, Tao
    Li, Jian-guo
    Wang, Juan
    Liang, Jingtao
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 20 - 27
  • [5] Experimental study of heat transfer capacity for loop heat pipe with flat disk evaporator
    Zhang, Zikang
    Zhang, Hao
    Ma, Zhenyuan
    Liu, Zhichun
    Liu, Wei
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [6] Experimental study on compact plate loop heat pipe
    Tian Y.
    Zhang H.
    Xu H.
    Tian C.
    Huagong Xuebao/CIESC Journal, 2021, 72 (06): : 3288 - 3295
  • [7] Heat transfer characteristics of flat evaporator loop heat pipe under high heat flux condition with different orientations
    Odagiri, Kimihide
    Nagano, Hosei
    APPLIED THERMAL ENGINEERING, 2019, 153 : 828 - 836
  • [8] Experimental study on flat type loop heat pipe with parallel evaporator
    Liu, Z.-C. (zcliu@hust.edu.cn), 1939, Science Press (34):
  • [9] Flat plate loop heat pipe with a novel evaporator structure
    Tsai, MC
    Yu, CS
    Kang, SW
    TWENTY-FIRST ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2005, 2005, : 187 - 190
  • [10] Experimental study on characteristics of gravity heat pipe with threaded evaporator
    Nikolaenko, Yu E.
    Pekur, D., V
    Sorokin, V. M.
    Kravets, V. Yu
    Melnyk, R. S.
    Lipnitskyi, L., V
    Solomakha, A. S.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 26