The use of anaerobic membrane bioreactor and reverse osmosis system for wastewater treatment

被引:0
作者
Zgavarogea, Ramona [1 ,2 ]
Covaliu, Cristina [1 ]
Iordache, Andreea [2 ]
Niculescu, Violeta [2 ]
Neacsa, Marin [1 ]
机构
[1] Faculty of Engineering and Management of Technological Systems, POLITEHNICA University of Bucharest, Romania
[2] National R and D Institute for Cryogenics and Isotopes Technologies - ICSI, Ramnicu Valcea, Romania
来源
UPB Scientific Bulletin, Series B: Chemistry and Materials Science | 2017年 / 79卷 / 02期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Domestic wastewater from Ramnicu Valcea town are treated by anaerobic membrane bioreactor (AMBR), followed by reverse osmosis (RO). The main studied objectives were the reduction of organic matter and the nutrient recovery, as well as the production of gas. The results confirmed the reduction of organic matter, nitrogen and phosphorous. However, it is necessary to add acid to prevent the precipitation / fouling of the RO unit. The total use of electricity for running the system is estimated at 4-7 kWh/m3.