Copper corrosion inhibition mechanism by combination of 2-mercaptobenzothiazole and magnetic treatment

被引:0
作者
Sun X. [1 ]
Qi Y. [1 ]
Dong S. [1 ]
机构
[1] School of Chemical Engineering, Northeast Electric Power University, Jilin
来源
Sun, Xuhui (sunxh@neepu.edu.cn) | 2018年 / Materials China卷 / 69期
关键词
Adsorption; Alternating magnetic field; Corrosion; Corrosion inhibitor; Surface;
D O I
10.11949/j.issn.0438-1157.20171062
中图分类号
学科分类号
摘要
In order to investigate whether magnetic treatment and 2-mercaptobenzothiazole (MBT) have synergistic effect on corrosion inhibition, corrosion rate of red copper was measured under different treatment conditions by weight loss method. The treatments included permanent magnetic field, alternative magnetic field, corrosion inhibitor MBT, and combination of MBT and magnetic field. Mechanism of corrosion inhibition was studied with assistance of SEM, XRD and ATR-FTIR. The results showed that permanent magnetic field had little effect on corrosion inhibition, but alternative magnetic field had some improvement on corrosion inhibition by forming compact oxide film on copper surface. Alternative magnetic field reduced water polarity and gave water molecules power and activity, which increased MBT solubility in water and adsorbance on copper surface. Therefore, combination of alternative magnetic field and MBT has synergistic effect on corrosion inhibition. To achieve same corrosion inhibition effect as MBT itself, synergistic effect could decrease MBT usage by 60%. Because MBT is dissolved in NaOH solution, less MBT will reduce alkali consumption and lower conductivity of cooling water in power generator. © All Right Reserved.
引用
收藏
页码:2120 / 2126
页数:6
相关论文
共 32 条
  • [1] Pu W.H., Yang D.W., Tuo W.Q., Et al., Study on compound inhibitor WY-1 used in anticorrosion of cooling water system for generator stator winding in copper, Journal of Changsha University of Electric Power (Natural Science), 3, pp. 248-252, (1995)
  • [2] Yan A.J., Lu Y.L., Study development of generator inner cooling water treatment technology, Northwest China Electric Power, 34, 1, pp. 5-7, (2006)
  • [3] Bai Y.M., Dai J., Song Z.H., Method and measures of optimizing generator cooling-water to prevent copper corrosion, Electrical Equipment, 7, 4, pp. 76-78, (2006)
  • [4] Fan S.P., Su W., Cao S.A., Research development of treatment technology for generator inner cooling water, Guangdong Electric Power, 4, pp. 7-11, (2015)
  • [5] Yan C.W., Cheng M., Zhao H., Inhibition of 2-mercaptobenzoxazole(MBO) for copper corrosion in NaCl and HCl solutions, Corrosion & Protection, 21, 6, pp. 255-256, (2000)
  • [6] He T., Tan C.Y., Tang J., Et al., Electrochemical behavior of copper passivated by MBT and HQ in 3.5% NaCl solution, The Chinese Journal of Nonferrous Metals, 5, pp. 1388-1395, (2013)
  • [7] Cui H., Tan C.Y., Zheng Y., Et al., Electrochemical behavior of copper passivated by BTA and MBT in NaCl solution, Journal of Central South University (Science and Technology), 42, 11, pp. 3336-3341, (2011)
  • [8] Sun X.H., Li W.C., Li B., Et al., Preparation, properties and application of ferrate in water treatment, Journal of Northeast Dianli University, 35, 4, pp. 33-39, (2015)
  • [9] Fathi A., Mohamed T., Claude G., Et al., Effect of a magnetic water treatment on homogeneous and heterogeneous precipitation of calcium carbonate, Water Research, 40, 10, pp. 1941-1950, (2006)
  • [10] Zaidi N.S., Sohaili J., Muda K., Et al., Magnetic field application and its potential in water and wastewater treatment systems, Separation & Purification Reviews, 43, 3, pp. 206-240, (2014)