Reliability analysis of reinforced concrete based on Wiener stochastic process in heavy salt soil electrified environment

被引:0
作者
Lu C. [1 ]
Wei Z. [2 ]
Qiao H. [1 ,3 ]
Li K. [1 ]
Qiao G. [1 ]
Yang B. [1 ]
机构
[1] School of Civil Engineering, Lanzhou University of Technology, Lanzhou
[2] State Key Laboratory of Advanced Processing and Recycling Built by Province and Ministry of Non-ferrous Metals, Lanzhou University of Technology, Lanzhou
[3] Western Center of Disaster Mitigation in Civil Engineering of Ministry of Education, Lanzhou University of Technology, Lanzhou
来源
Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology) | 2020年 / 51卷 / 08期
基金
中国国家自然科学基金;
关键词
Electrify to accelerate; Electrochemistry; Reinforced concrete; Reliability; Saline soil; Wiener random process;
D O I
10.11817/j.issn.1672-7207.2020.08.021
中图分类号
学科分类号
摘要
In order to explore the influence of corrosion ion and current on the durability of reinforced concrete in the service environment, reinforced concrete prismatic specimens of three strength grades were placed in the heavy saline soil for constant current acceleration test. The electrochemical workstation and crack detector were used for nondestructive testing regularly. The degradation process of reinforced concrete durability was analyzed by polarization curve and alternating current impedance graph. Non-monotone Wiener stochastic degradation process was selected for modeling and maximum likelihood method was used for parameter estimation. According to the crack width of concrete and crack failure criterion, the failure threshold of corrosion current density in the electrified accelerated environment of saline soil was obtained, and the relationship curve between electrified time and reliability was established. The results show that in the electrified environment of saline soil, corrosive ions enter into the concrete through diffusion, infiltration and electric field adsorption, and then migrate to the surface of reinforcement. pH value of the concrete decreases and the conductivity increases. The polarization curve moves toward the negative potential. The probability and rate of corrosion increase, and the alternating current impedance spectrum shows double capacitive reactance arc. At the beginning of power on, the arc radius of low frequency capacitive reactance decreases sharply and shrinks to the real part of impedance. When the crack width is 0.2 mm, the failure thresholds of corrosion current density of reinforced concrete for C35, C40 and C45 are 2.353, 1.817 and 1.187 μA/cm2, respectively. The higher the strength grade of concrete is, the longer the reliability is maintained at 1.0, and the stronger the anti erosion ability is. Under the coupling action of corrosive ions and current, the degree of reliability for C35, C40 and C45 specimens decrease to below 1.0 at 160, 240 and 430 h, respectively. The longer the time of power on is, the lower the reliability of reinforced concrete is. © 2020, Central South University Press. All right reserved.
引用
收藏
页码:2266 / 2276
页数:10
相关论文
共 21 条
  • [1] SU Yu, WU Chengqing, LI Jun, Et al., Development of novel ultra-high performance concrete: From material to structure, Construction and Building Materials, 135, pp. 517-528, (2017)
  • [2] YOO D Y, YOON Y S., A review on structural behavior, design, and application of ultra-high-performance fiber-reinforced concrete, International Journal of Concrete Structures and Materials, 10, 2, pp. 125-142, (2016)
  • [3] CAO Zhonglu, Corrosion behaviors of reinforcing steel in concrete with various moisture contents, Key Engineering Materials, 805, pp. 100-105, (2019)
  • [4] JIANG Le, WENG Xingzhong, YAN Xiangcheng, Et al., Moisture diffusion coefficient and internal deterioration evolving rule of concrete exposed to freeze-thaw cycles, Journal of Central South University(Science and Technology), 46, 8, pp. 3118-3123, (2015)
  • [5] TANG Kangkang, Stray alternating current(AC) induced corrosion of steel fibre reinforced concrete, Corrosion Science, 152, pp. 153-171, (2019)
  • [6] JAMES A, BAZARCHI E, CHINIFORUSH A A, Et al., Rebar corrosion detection, protection, and rehabilitation of reinforced concrete structures in coastal environments: a review, Construction and Building Materials, 224, pp. 1026-1039, (2019)
  • [7] WITTMANN F H, ZHAO Tiejun, JIANG Fuxiang, Et al., Influence of combined actions on durability and service life of reinforced concrete structures exposed to aggressive environment, Restoration of Buildings and Monuments, 18, 2, pp. 105-112, (2012)
  • [8] WU Lingjie, KOU Xinjian, ZHOU Yongjun, Et al., Time-dependent chloride transport in existing concrete docks, Journal of Shanghai Jiao Tong University, 51, 4, pp. 444-449, (2017)
  • [9] LI Jingpei, LI He, Service life prediction model of concrete square piles in marine environment, Journal of Tongji University(Natural Science Edition), 44, 9, pp. 1371-1376, (2016)
  • [10] SHAO Wei, LI Jingpei, Service life prediction of reinforced concrete pipe pile due to chloride ion corrosion, Journal of Tongji University (Natural Science Edition), 42, 12, pp. 1820-1825, (2014)