Heat transfer and fluid flow characteristics of a backward-facing step flow in a duct

被引:0
作者
Inaoka, Kyoji [1 ]
Senda, Mamoru [1 ]
机构
[1] Department of Mechanical Engineering, Doshisha University, Kyotanabe
来源
Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B | 2013年 / 79卷 / 804期
关键词
Backward-facing step; Flow reattachment; Heat transfer; PIV; Three-dimensional flow;
D O I
10.1299/kikaib.79.1651
中图分类号
学科分类号
摘要
Spatial distributions of local heat transfer coefficients on the bottom wall downstream of a backward-facing step in a duct flow have been measured by making use of a thermo-sensitive liquid crystal sheet. Heat transfer experiments and three components of the time averaged velocity measurements by 2D PIV have been done for wide variety of the flow Reynolds number ranging from laminar (1000) to turbulent (10000) flow regimes for the stepped duct having an aspect ratio of 16 and expansion ratio of 2. Obtained local Nusselt number changes not only in the streamwise direction but also spanwise direction, that is, the maximum Nusselt number always appears near the side wall region even if the flow Reynolds number is varied. Strong downward flow from the step induced along the side xvall produces the secondary flow toward the central part of the duct and the area where this secondary flow exists agrees well to the area of the high heat transfer coefficient. The s(reamwise location of the maximum Nusselt number quickly moves closer to the step as the Reynolds number increases from 1000 to 2300, then it gradually moves to the downstream from 2300 to 10000. This streamwise location corresponds quite well to that of the flow reattachment for each Reynolds number. A pair of the vertical vortices having axes in the wall normal direction is found to be generated at the corner just behind the step near the side wall and this causes the minimum heat transfer there. © 2013 The Japan Society of Mechanical Engineers.
引用
收藏
页码:1651 / 1663
页数:12
相关论文
共 12 条
[1]  
Eaton J.K., Johnston J.P., A review of research on subsonic turbulent flow reattachment, AIAA Journal, 19, pp. 1093-1100, (1981)
[2]  
Armaly B.F., Durst F., Pereira J.C.F., Schonung B., Experimental and theoretical investigation of backward-facing step flow, Journal of Fluid Mechanics, 127, pp. 473-496, (1983)
[3]  
Aung W., An experimental study of laminar heat transfer downstream of backsteps, Journal of Heat Transfer, 105, pp. 823-829, (1983)
[4]  
Vogel J.C., Eaton J.K., Combined heat transfer and fluid dynamic measurements downstream of a backward-feeing step, Journal of Heat Transfer., 107, pp. 922-929, (1985)
[5]  
Kondoh T., Nagano Y., Tsuji T., Computational study of laminar heat transfer downstream of a backward-facing step, International Journal of Heat Mass Transfer, 36, pp. 577-591, (1993)
[6]  
Le H., Moin P., Kim J., Direct numerical simulation of turbulent flow over a backward-facing step, Journal of Fluid Mechanics, 330, pp. 349-374, (1997)
[7]  
Kasagi N., Matsunaga A., Three-dimensional particle-tracking velocimetry measurement of turbulence statistics and energy budget in a backward-facing step flow, International Journal of Heat and Fluid Flow, 16, pp. 477-485, (1995)
[8]  
Fruichi N., Hachiga T., Kumada M., An experimental investigation of a large-scale structure of a two-dimensional backward-facing step by using advanced multi-point ldv, Experiments in Fluids, 36, pp. 274-281, (2004)
[9]  
Papadopoulos G., Otugen M.V., Separating and reattaching flow structure in a suddenly expanding rectangular duct, Journal of Fluids Engineering, 117, pp. 17-23, (1995)
[10]  
Chiang T.P., Sheu T.W.H., A numerical revisit of backward-facing step flow problem, Physics of Fluids, 11, pp. 862-874, (1999)