Theory and developments in an unobtrusive cardiovascular system representation: Ballistocardiography

被引:120
作者
Pinheiro E. [1 ]
Postolache O. [1 ]
Girão P. [1 ]
机构
[1] Instituto de Telecomunicações, Instituto Superior Técnico, 1049-001, Lisboa, Torre Norte piso 10
关键词
Ballistocardiography; Biomedical measurements; Cardiac signal analysis; Cardiovascular system monitoring; Unobtrusive instrumentation;
D O I
10.2174/1874120701004010201
中图分类号
学科分类号
摘要
Due to recent technological improvements, namely in the field of piezoelectric sensors, ballistocardiography an almost forgotten physiological measurement-is now being object of a renewed scientific interest. Transcending the initial purposes of its development, ballistocardiography has revealed itself to be a useful informative signal about the cardiovascular system status, since it is a non-intrusive technique which is able to assess the body's vibrations due to its cardiac, and respiratory physiological signatures. Apart from representing the outcome of the electrical stimulus to the myocardium - which may be obtained by electrocardiography -the ballistocardiograph has additional advantages, as it can be embedded in objects of common use, such as a bed or a chair. Moreover, it enables measurements without the presence of medical staff, factor which avoids the stress caused by medical examinations and reduces the patient's involuntary psychophysiological responses. Given these attributes, and the crescent number of systems developed in recent years, it is therefore pertinent to revise all the information available on the ballistocardiogram's physiological interpretation, its typical waveform information, its features and distortions, as well as the state of the art in device implementations. © 2010 Bentham Open.
引用
收藏
页码:201 / 216
页数:15
相关论文
共 166 条
[1]  
Ballistocardiography a bibliography, NASA SP-7021 (FAA AM 65-15), (1965)
[2]  
Scarborough W.R., Baker B.M., Ballistocardiography appraisal of current status, Circulation, 16, pp. 971-975, (1957)
[3]  
Gubner R.S., Rodstein M., Ungerleider H.E., Ballistocardiography an appraisal of technic, physiologic principles, and clinical value, Circulation, 7, pp. 268-286, (1953)
[4]  
Gordon J.W., On certain molar movements of the human body produced by the circulation of the blood, J. Anat. Physiol, 11, (1877)
[5]  
Henderson Y., The mass-movements of the circulation as shown by a recoil curve, Am. J. Physiol, 14, (1905)
[6]  
Starr I., Rawson A.J., Schroeder H.A., Apparatus for recording the heart's recoil and the blood's impacts in man (ballistocardiograph), experiments on the principles involved, records in normal and abnormal conditions, Annual Meeting. Am. J. Physiol, 123, (1938)
[7]  
Starr I., Rawson A.J., Schroeder H.A., Joseph N.R., The estimation of cardiac output and the determination of the blood's impacts (ballistocardiogram), Proceedings Am. Soc. Clin. Invest. 30th Annual Meeting, J. Clin. Invest, 17, (1938)
[8]  
Starr I., Rawson A.J., Schroeder H.A., Joseph N.R., Studies on the estimation of cardiac output in man, and of abnormalities in cardiac function from the heart's recoil and the blood's impact
[9]  
the ballistocardiogram, Am. J. Physiol, 127, (1939)
[10]  
Nickerson J.L., Curtis H.J., The design of the ballistocardiograph, Am. J. Physiol, 142, (1944)