A study for determining the hydraulic conductivity of geosynthetic clay liners in the laboratory

被引:0
作者
Oren, Ali Hakan [1 ]
Demirkiran, Havva [2 ]
机构
[1] Inşaat Mühendisliʇi Bölümü, Dokuz Eylül Üniversitesi, Izmir, Turkey
[2] Dokuz Eylül Üniversitesi, Fen Bilimleri Enstitüsü, Izmir, Turkey
来源
Teknik Dergi/Technical Journal of Turkish Chamber of Civil Engineers | 2015年 / 26卷 / 04期
关键词
Testing - Deionized water - Geosynthetic materials - Waste disposal - Hydraulic conductivity;
D O I
暂无
中图分类号
学科分类号
摘要
This study was prepared to show how to perform the hydraulic conductivity test on geosynthetic clay liners (GCLs) and how to evaluate the results. In the content of this study, four types of GCLs were subjected to hydraulic conductivity tests using deionized water and tap water. The tests lasted six months and the final hydraulic conductivities of GCLs were measured within the range of 7.1 × 10 -10 - 1.4 × 10 -9 cm/s. To terminate the tests, it was checked to see whether hydraulic stability was achieved or not throughout the test duration. To do this, hydraulic conductivity ratio was defined and it was accepted that the stability was assured when this ratio was reduced below 1.5. Besides, it was found that the effect of permeant water and the GCL types on the hydraulic conductivity were limited. The results of this study were also compared with the hydraulic conductivities that were reported in the literature as a function of effective stress. It is concluded that the findings of this study are in agreement with those in the literature.
引用
收藏
页码:7191 / 7213
相关论文
empty
未找到相关数据