Stability analysis of three-phase Vienna rectifier AC cascade system based on reduced order model

被引:0
作者
Dang C. [1 ]
Tong X. [1 ]
Song W. [1 ]
Huang J. [1 ]
机构
[1] School of Automation and Information Engineering, Xi'an University of Technology, Xi'an
来源
Dianli Zidonghua Shebei/Electric Power Automation Equipment | 2018年 / 38卷 / 10期
基金
中国国家自然科学基金;
关键词
Impedance regulator; LC filter; Reduced order model; Stability; Three-level Vienna rectifier;
D O I
10.16081/j.issn.1006-6047.2018.10.021
中图分类号
学科分类号
摘要
Taking the small signal stability analysis of three-phase Vienna rectifier AC cascade system as the research object, the simplified small signal stability criterion in dq coordinate system is put forward, further, a Vienna rectifier impedance equation for small signal stability analysis in cascade system is given. Finally, a virtual impedance method is proposed to improve the small signal stability of Vienna rectifier system. A complete simulation and test model is built, and the detailed theoretical analysis and design scheme of virtual impedance are given. The results show the correctness of the small signal stability analysis and the proposed virtual impedance method. © 2018, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:133 / 139
页数:6
相关论文
共 18 条
[1]  
Liu S., Zhang G., Shi S., Et al., Analysis of inter-pole coupling effect and faulty pole selection for HVDC transmission line, Electric Power Automation Equipment, 37, 4, (2017)
[2]  
Dang C., Tong X., Huang J., Et al., The neutral point-potential and current model predictive control method for Vienna rectifier, Journal of the Franklin Institute, 354, 17, pp. 7605-7623, (2017)
[3]  
Lu X., Xie Y., Gui C., Et al., Vienna rectifier control strategy based on passivity control and sliding mode variable structure control, Electric Power Automation Equipment, 34, 10, pp. 110-115, (2014)
[4]  
Gao T., Zhong Z., Zhang S., Et al., Neutral-point voltage balancing based on one-cycle control for three-phase three-level PFC rectifier, Electric Power Automation Equipment, 36, 7, pp. 111-117, (2016)
[5]  
Li J., Jiang J., System stability of battery charger for battery electric vehicle, Electric Power Automation Equipment, 32, 9, pp. 13-17, (2012)
[6]  
Teng Y., Wang X., Yu H., Et al., A grid impedance shaping method to improve robustness of LCL type grid-connected inverter against grid impedance variation, Proceedings of the CSEE, 35, pp. 197-204, (2015)
[7]  
Lu J., Cai X., Zhang J., AC-and DC-side impedance models of modular multilevel converter, Electric Power Automation Equipment, 37, 1, pp. 131-135, (2017)
[8]  
Yang D., Ruan X., Wu H., A virtual impedance method to improve the performance of LCL-type grid-connected inverters under weak grid conditions, Proceedings of the CSEE, 34, 15, pp. 2327-2335, (2014)
[9]  
Jian S., Impedance-based stability criterion for grid connected inverters, IEEE Transactions on Power Electronics, 26, 11, pp. 3075-3078, (2011)
[10]  
Zhang H., Stability of AC three-phase voltage source PWM rectifier cascade system, (2014)