Development of non-contact electromagnetic sensor for the meniscus velocity measurement of molten metal flow

被引:0
|
作者
Iguchi, Manabu [1 ]
Hanazaki, Kazuharu [1 ]
Terauchi, Yukio [1 ]
机构
[1] Graduate School of Engineering, Hokkaido University, North 13 West 8 Kita-ku, Sapporo 060-8628, Japan
来源
| 2002年 / Iron and Steel Institute of Japan卷 / 88期
关键词
Bandpass filters - Continuous casting - Liquid metals - Molds - Oscillators (mechanical) - Sensors - Wave propagation;
D O I
10.2355/tetsutohagane1955.88.10_629
中图分类号
学科分类号
摘要
A velocimeter was proposed for the measurement of the surface velocity of molten metal flow. Cold model experiments were carried out to evaluate its accuracy. Wave motions were imposed on the molten Wood's metal surface by means of the Lorentz force. The propagation times of the waves in the upstream and downstream directions were detected with two level sensors. The surface velocity of molten Wood's metal flow was calculated from the propagation time difference and the distance between the two level sensors. The surface velocity could be accurately measured even if wave motions, i.e., meniscus level fluctuations caused by other external and internal oscillations existed on the molten metal surface. These disturbances can readily be removed using a narrow band pass filter because the frequency of the imposed wave motions is predetermined.
引用
收藏
相关论文
共 50 条
  • [31] Non-contact and contact measurement system for detecting projectile position in electromagnetic launch bore
    Xu, Weidong
    Yuan, Weiqun
    Xu, Rong
    Zhao, Hui
    Cheng, Wenping
    Zhang, Dongdong
    Zhao, Ying
    Yan, Ping
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (12)
  • [32] A Study on the Shape Evaluation using Non-contact Electromagnetic Measurement System
    Kim, Jae Min
    Yun, Seung Ho
    Won, Hyuk
    Park, Gwan Soo
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2010, 20 (02): : 45 - 51
  • [33] THEORETICAL INVESTIGATION OF NON-CONTACT VELOCITY MEASUREMENT USING AN OPTICAL GRID
    KREUTZER, P
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1975, 83 (06): : 289 - 294
  • [34] Gingival blood flow measurement with a non-contact laser flowmeter
    Matsuki, M
    Xu, YB
    Nagasawa, T
    JOURNAL OF ORAL REHABILITATION, 2001, 28 (07) : 630 - 633
  • [35] Non-contact temperature measurement
    Metallurgia, 1995, 62 (02):
  • [36] ELECTROMAGNETIC NON-CONTACT GEARS: PRELUDE
    Parashar, Prachi
    Milton, Kimball A.
    Cavero-Pelaez, Ines
    Shajesh, K. V.
    PROCEEDINGS OF THE NINTH CONFERENCE ON QUANTUM FIELD THEORY UNDER THE INFLUENCE OF EXTERNAL CONDITIONS (QFEXT09), 2010, : 48 - 54
  • [37] NON-CONTACT SPEED MEASUREMENT
    KENYON, M
    VANHOEK, HC
    PORTER, CA
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1981, 37 (06): : 114 - 117
  • [38] PROGRESS IN NON-CONTACT MEASUREMENT
    LEWIS, GE
    CME-CHARTERED MECHANICAL ENGINEER, 1981, 28 (08): : 31 - 32
  • [39] Non-contact temperatures measurement
    Materiales de Construccion, 62 (238):
  • [40] NON-CONTACT MEASUREMENT BY RADIOACTIVITY
    BOND, A
    PROCESS ENGINEERING, 1975, (MAR) : 62 - 63