Experiment on shear behavior of reinforced concrete beams strengthened with prestressed high strength steel wire mesh

被引:0
作者
Guo, Jun-Ping [1 ]
Deng, Zong-Cai [1 ]
Lu, Hai-Bo [2 ]
Lin, Jin-Song [2 ]
机构
[1] College of Architecture and Civil Engineering, Beijing University of Technology
[2] Beijing Hand and Hand Building Technology Development Co., Ltd
来源
Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition) | 2014年 / 44卷 / 04期
关键词
Civil engineering structure; High strength steel wire; Prestress; Reinforced concrete beam; Shear capacity;
D O I
10.13229/j.cnki.jdxbgxb201404011
中图分类号
学科分类号
摘要
The shear behavior of concrete beams reinforced with U-shaped high strength steel wire mesh at different prestress levels with new tension and anchor system is investigated. Six beams reinforced with high strength steel wire mesh at different prestress levels and shear span to depth ratio of 2.2 and 1.65 (3 specimens for each ratio) were tested and compared with one reinforced concrete beam without high strength steel wire mesh. The results show that the load capacity and the stiffness of beams reinforced with prestressed steel wire mesh increase with the prestress level of the steel wire mesh. If the prestress level is greater than 0.3, the increase rate of the load capacity is reduced. A model to predict the shear capacity of the beams is proposed. The predicted results using this model are in good agreement with the experiment results. The proposed model can be used for theoretical analysis and design of concrete beams strengthened with prestressed steel wire mesh.
引用
收藏
页码:968 / 977
页数:9
相关论文
共 10 条
[1]  
Wu G., Guang C.-F., Tian Y., Et al., Investigation on construction technique and effect of shear strengthening of RC beams with prestressed high strength wires, Building Structure, SUPPL.1, pp. 312-314, (2007)
[2]  
Kim S.Y., Yang K.H., Byun H.Y., Et al., Tests of reinforced concrete beams strengthened with wire rope units, Engineering Structures, 29, pp. 2711-2722, (2007)
[3]  
Yang K.H., Byun H.Y., Ashour A.F., Shear strengthening of continuous reinforced concrete T-beams using wire rope units, Engineering Structures, 31, 5, pp. 1154-1165, (2009)
[4]  
Yang J.-M., Study on shear behavior of RC beam retrofitted by prestressed closed wire rope units, (2011)
[5]  
Yang J.-M., Guo Z.-X., Huang Q.-X., Method for calculating shear capacity of RC beams strengthened with prestressed wire stirrups, Journal of Huaqiao University (Natural Science), 32, 4, pp. 422-426, (2011)
[6]  
Yu T.-L., Hou X.-B., Tian L.-L., The shear resistant effect of RC beam strengthened with SWR external prestressing under cracking width of the original beam, International Conference on Civil Engineering and Transportation, pp. 1463-1467, (2011)
[7]  
Yu T.-L., Li X.-Y., Ma Q., Et al., Study on the method for calculating shear capacity of RC beams strengthened with externally prestressed wire rope, International Conference on Civil Engineering and Transportation, pp. 1442-1446, (2011)
[8]  
Yu T.-L., Ma Q., Tian L.-L., Et al., Test study on the resisting shear strengthening effect with external pre-stressed wire rope, International Conference on Civil Engineering and Transportation, pp. 243-249, (2011)
[9]  
Yu T.-L., Shi W.-Z., Yu G.-Y., Et al., Experimental study on the influence of wire rope arrangement with the shear strengthening, Journal of Wuhan University of Technology, 34, 8, pp. 107-112, (2012)
[10]  
(2006)