Determination of Mold Invasion and Occupants' Respiratory Health in University Laboratories

被引:2
作者
Azahar, Sharifah Nuradila Syed [1 ]
Sopian, Nor Ashikin [1 ,2 ]
Abdull, Norhidayah [1 ]
Hussin, Nor Husna Mat [1 ]
机构
[1] Univ Malaysia Pahang Al Sultan Abdullah, Fac Ind Sci & Technol, Kuantan 26300, Pahang, Malaysia
[2] Univ Airlangga, Fac Publ Hlth, Dept Occupat Hlth & Safety, Surabaya 60115, Indonesia
关键词
DMAT; Mold; Indoor air quality; Respiratory symptoms; INDOOR AIR-QUALITY; BACTERIA;
D O I
10.4209/aaqr.240119
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The presence of mold can have detrimental effects on both the integrity of buildings and occupants' health. This cross-sectional study aimed to explore the extent of mold invasion on the respiratory health of occupants at the university laboratories through the integration of quantitative bioaerosol sampling and semi-quantitative strategies. The latter approach involved the application of the NIOSH Dampness and Mold Assessment Tool (DMAT) to assess the damage, presence of mold and dampness in the laboratories. Instruments such as biostage impactors and air velocity meters were used to collect samples and data on the biological and physical parameters of indoor air quality (IAQ). Furthermore, a validated questionnaire was also used to gather information on respiratory symptoms among occupants. The findings of DMAT showed that "visible mold" and "wet/damp" were the most significant factors based on the lab classification. Meanwhile the variables "damage/stain" and "room" were the most significant variables when comparing numbers of doors (p < 0.05). When assessing the physical and biological parameters in the laboratories, it was disclosed that temperature and total bacterial count were the most significant factors among all (p < 0.001). Interestingly, relative humidity significantly correlated well with both total fungal count (r2 = 0.362) and total bacteria count (r2 = 0.202). The completed questionnaire indicated that 18.57% of the occupants were technical staff while the remaining 81.43% were students. It portrayed that cough (p = 0.002) was the most significant respiratory symptom with the highest prevalence of 74.3% among occupants. In addition, the logistic regression model disclosed that all IAQ parameters significantly influenced cough symptoms, except temperature (r2 = 0.641, p < 0.05). In conclusion, this study adds to our understanding of the complex link between indoor mold exposure, IAQ parameters, and respiratory health in laboratory occupants. The high prevalence of cough symptoms and their association with IAQ indicators emphasized the importance of focused intervention strategies to enhance indoor environmental quality.
引用
收藏
页数:12
相关论文
共 45 条
[21]  
Joshi Sumedha M, 2008, Indian J Occup Environ Med, V12, P61, DOI 10.4103/0019-5278.43262
[22]   Detection of pathogenic bacteria during rhinovirus infection is associated with increased respiratory symptoms and asthma exacerbations [J].
Kloepfer, Kirsten M. ;
Lee, Wai Ming ;
Pappas, Tressa E. ;
Kang, Theresa J. ;
Vrtis, Rose F. ;
Evans, Michael D. ;
Gangnon, Ronald E. ;
Bochkov, Yury A. ;
Jackson, Daniel J. ;
Lemanske, Robert F., Jr. ;
Gern, James E. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2014, 133 (05) :1301-U504
[23]   Airborne fungal species associated with mouldy and non-mouldy buildings - effects of air change rates, humidity, and air velocity [J].
Knudsen, Sofie M. ;
Gunnarsen, Lars ;
Madsen, Anne Mette .
BUILDING AND ENVIRONMENT, 2017, 122 :161-170
[24]   Experiment and simulation for the effect of window opening behavior on indoor air status points in wuhan area in summer [J].
Mao, Qianjun ;
You, Jingnan ;
Li, Tao .
CASE STUDIES IN THERMAL ENGINEERING, 2022, 37
[25]  
Isa KNM, 2024, Malaysian Journal of Medicine and Health Sciences, V20, P168, DOI [10.47836/mjmhs.20.1.22, 10.47836/mjmhs.20.1.22, DOI 10.47836/MJMHS.20.1.22]
[26]   Interaction of indoor air contaminants and respiratory health among children in the daycare centers [J].
Najib, Siti Aiman Husna Mohd ;
Jalaludin, Juliana ;
Feisal, Nur Azalina Suzianti ;
Faruk, Tashnia ;
Khan, Md Firoz .
AIR QUALITY ATMOSPHERE AND HEALTH, 2024, 17 (08) :1677-1688
[27]   Prevalence, codetection and seasonal distribution of upper airway viruses and bacteria in children with acute respiratory illnesses with cough as a symptom [J].
O'Grady, K. F. ;
Grimwood, K. ;
Sloots, T. P. ;
Whiley, D. M. ;
Acworth, J. P. ;
Phillips, N. ;
Goyal, V. ;
Chang, A. B. .
CLINICAL MICROBIOLOGY AND INFECTION, 2016, 22 (06) :527-534
[28]  
Onwusereaka C.O., 2022, Malays. J. Med. Health Sci, V18, P62
[29]   Variability and health impact of air pollutants and bioaerosols in multi-functional indoor environments with mechanical ventilation system [J].
Othman, Murnira ;
Latif, Mohd Talib ;
Hamid, Haris Hafizal Abd ;
Abu Bakar, Nor Hidayu ;
Mohamad, Nur Husna ;
Haron, Nur Farahiyah ;
Noraini, Nor Mohd Razif .
JOURNAL OF BUILDING ENGINEERING, 2024, 90
[30]   NIOSH Dampness and Mold Assessment Tool (DMAT): Documentation and Data Analysis of Dampness and Mold-Related Damage in Buildings and Its Application [J].
Park, Ju-Hyeong ;
Cox-Ganser, Jean M. .
BUILDINGS, 2022, 12 (08)