Characteristics of X-ray and gamma radiation detectors based on polycrystalline CdTe and CdZnTe films

被引:3
|
作者
Utamuradova Sh.B. [1 ]
Muzafarova S.A. [1 ]
Abdugafurov A.М. [1 ]
Fayzullaev K.M. [1 ]
Naurzalieva E.M. [1 ]
Rakhmanov D.A. [1 ]
机构
[1] Institute of Semiconductor Physics and Microelectronics, the National University of Uzbekistan 20 Yangi Almazar st., Tashkent
来源
Utamuradova, Sh.B. (sh-utamuradova@yandex.ru) | 1600年 / ORION Research-and-Production Association卷
关键词
Dark current; Detector intermediate layer; Energy resolution; Film; Irradiation; Mobility; Radiation; Solid solution; Structure;
D O I
10.51368/1996-0948-2021-4-81-86
中图分类号
学科分类号
摘要
Based on CdTe and CdZnTe detectors a number of promising devices were created, which found their application in metallurgy, in solving the problems of customs control and control of nuclear materials, as well as matrix detectors created for the manufacture of medical devices and devices for space research. Detectors, created on the basis of polycrystalline semiconductor CdTe and CdZnTe films with a columnar structure on a molybdenum substrate with a thickness d = 30/150 μm, had a specific resistance P > 105108 Ω-cm. The energy resolution of the CdTe and CdZnTe detectors at room temperature reached ~ 5 keV on the 59.6 keV 241Am line. © Утамурадова Ш. Б., Музафарова С. А., Абдугафуров А. М., Файзуллаев К. М., Наурзалиева Э. М., Рахманов Д. А., 2021
引用
收藏
页码:81 / 86
页数:5
相关论文
共 50 条
  • [1] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) : 297 - 309
  • [2] Radiation Detectors for X-Ray and Gamma-Ray Spectroscopy
    G. F. Knoll
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 243 : 125 - 131
  • [3] A photoelectric study of charge-carrier collection in CdZnTe-based detectors of x-ray and γ radiation
    L. A. Kosyachenko
    E. L. Maslyanchuk
    I. M. Rarenko
    V. M. Sklyarchuk
    Semiconductors, 2004, 38 : 981 - 986
  • [4] Hard x-ray response of pixellated CdZnTe detectors
    Abbene, L.
    Del Sordo, S.
    Caroli, E.
    Gerardi, G.
    Raso, G.
    Caccia, S.
    Bertuccio, G.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (12)
  • [5] Fabrication and characterization of X-ray array detectors based on polycrystalline PbI2 thick films
    Xinghua Zhu
    Hui Sun
    Dingyu Yang
    Jun Yang
    Xu Li
    Xiuying Gao
    Journal of Materials Science: Materials in Electronics, 2014, 25 : 3337 - 3343
  • [6] CdTe and CdZnTe semiconductor gamma detectors equipped with ohmic contacts
    Lachish, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) : 146 - 149
  • [7] New neutron, gamma and X-ray detectors
    Lobanov, NS
    Zinov'ev, OA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (04) : 490 - 492
  • [8] New Neutron, Gamma and X-Ray Detectors
    N. S. Lobanov
    O. A. Zinov'ev
    Instruments and Experimental Techniques, 2002, 45 : 490 - 492
  • [9] CdZnTe detectors for gamma spectroscopy and x-ray photon counting at 250 x 106 photons/(mm2s)
    Prokesch, Michael
    Soldner, Stephen A.
    Sundaram, Arunmozhi G.
    JOURNAL OF APPLIED PHYSICS, 2018, 124 (04)
  • [10] Reduction of Leakage Currents in CdZnTe-Based X-ray and γ-ray Detectors: a II-VI Semiconductor Superlattice Approach
    Chang, Y.
    Grein, C. H.
    Becker, C. R.
    Wang, X. J.
    Sivananthan, S.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII, 2010, 7805