Effect to online energy measurement device for long-pulse laser by laser pulse width

被引:2
作者
Wei J. [1 ]
Guan Y. [1 ]
Zhou S. [1 ]
Peng Y. [1 ]
Hu X. [1 ]
Zhang K. [1 ]
机构
[1] Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang
来源
Zhongguo Jiguang/Chinese Journal of Lasers | 2010年 / 37卷 / 04期
关键词
Compensate; Heat conduction; Laser energy; Measurement; Online measurement device;
D O I
10.3788/CJL20103704.1088
中图分类号
学科分类号
摘要
Heat bridge in the online energy measurement device for long-pulse laser enhances heat conduction effect. The research was done to assure the value of the effect on measurement result so as to correct the measurement result. Curves of temperature was divided into three parts, each part was analyzed with Fourier heat law, heat conduction equations and energy conservation law. Relationship between energy loss and device parameter was obtained, and experiment research was done. Experiment data was fitted and conclusion was drawn: heat loss rate is decided by pulse length, heat conduction coefficient of material, length of heat bridge, quality of heat absorption body, and et al.. These parameters are decided according to experiment interval and precision requirement. Theory value and experiment result have a good coherence. Its deviation is 2.9%.
引用
收藏
页码:1088 / 1092
页数:4
相关论文
共 10 条
[1]  
Wei J., Zhang K., Qian S., Et al., Evaluation of uncertainty in online energy measurement of high energy-laser, High Power Laser and Particle Beams, 19, 7, pp. 1102-1106, (2007)
[2]  
Wei J., Guan Y., Zhou S., Et al., Online calibration methods for high energy laser energy measurement equipment, Chinese J. Lasers, 36, 9, pp. 2399-2403, (2009)
[3]  
Wei J., Zhang K., Zhou S., Research on calibration of high-energy-laser calorimeter, High Power Laser and Particle Beams, 20, 11, pp. 1798-1802, (2008)
[4]  
Su Y., Wan M., High Energy Laser System, (2004)
[5]  
Yu J., Study on the watt-level primary standard for laser power, Advanced Measurement, 23, 1, pp. 38-41, (1998)
[6]  
Hu J., Liu X., Zhang G., Et al., A real-time energy meter for medical excimer laser, Chinese J. Lasers, 34, 12, pp. 1732-1735, (2007)
[7]  
Incropera F.P., DwWitt D.P., Bergman T.L., Fundamentals of Heat and Mass Transfer, (2007)
[8]  
Zhang F., Liu W., Li L., Et al., Application of heat conduction equation in phase extraction of speckle fringe pattern, Acta Optica Sinica, 28, 8, pp. 1475-1479, (2008)
[9]  
Wang L., Yang Z., Li G., Et al., Research on temperature characteristics of absolute calorimetric energy meter for high-energy laser, Applied Optics, 26, 5, pp. 14-16, (2005)
[10]  
Li D., Zhao Y., He H., Et al., Exponential fitting of laser damage threshold and analysis of testing errors, Chinese J. Lasers, 35, 2, pp. 273-275, (2008)